نتایج جستجو برای: hybrid phantoms

تعداد نتایج: 202911  

2015
Franziska Henrich Helene Rahn Stefan Odenbach

The magnetic heating treatment (MHT) is well known as a promising therapy for cancer diseases. Depending on concentration and specific heating power of the magnetic material as well as on parameters of the magnetic field, temperatures between 43 and 55 1C can be reached. This paper deals with the evaluation of heat distribution around such a heat source in a tissue model, thereby focusing on th...

2005
Xu He Ji Hoon Shin Hyo-Cheol Kim Cheol Woong Woo Sung Ha Woo Won-Chan Choi Jong-Gyu Kim Jin-Oh Lim Tae-Hyung Kim Chang Jin Yoon Weechang Kang Ho-Young Song

OBJECTIVE We wanted to evaluate the feasibility and usefulness of a newly designed balloon sheath for gastrointestinal guidance and access by conducting a phantom study. MATERIALS AND METHODS The newly designed balloon sheath consisted of an introducer sheath and a supporting balloon. A coil catheter was advanced over a guide wire into two gastroduodenal phantoms (one was with stricture and o...

2012
Guy Lamouche Brendan F. Kennedy Kelsey M. Kennedy Charles-Etienne Bisaillon Andrea Curatolo Gord Campbell Valérie Pazos David D. Sampson

We review the development of phantoms for optical coherence tomography (OCT) designed to replicate the optical, mechanical and structural properties of a range of tissues. Such phantoms are a key requirement for the continued development of OCT techniques and applications. We focus on phantoms based on silicone, fibrin and poly(vinyl alcohol) cryogels (PVA-C), as we believe these materials hold...

Journal: :Applied optics 2003
John A Viator Bernard Choi Martin Ambrose Jerome Spanier J Stuart Nelson

We have designed a photoacoustic probe for port-wine stain (PWS) depth measurements consisting of optical fibers for laser light delivery and a piezoelectric element for acoustic detection. We characterized the capabilities and limitations of the probe for profiling PWS skin. The probe induced and measured photoacoustic waves in acrylamide tissue phantoms and PWS skin in vivo. The optical prope...

2016
Vassilios S. Vassiliou Ee Ling Heng Peter D. Gatehouse Jacqueline Donovan Claire E. Raphael Shivraman Giri Sonya V. Babu-Narayan Michael A. Gatzoulis Dudley J. Pennell Sanjay K. Prasad David N. Firmin

BACKGROUND Magnetic resonance imaging (MRI) phantoms are routinely used for quality assurance in MRI centres; however their long term stability for verification of myocardial T1/ extracellular volume fraction (ECV) mapping has never been investigated. METHODS Nickel-chloride agarose gel phantoms were formulated in a reproducible laboratory procedure to mimic blood and myocardial T1 and T2 val...

Journal: :Medical physics 2011
Deirdre M King Andrew J Fagan Carmel M Moran Jacinta E Browne

PURPOSE A range of anatomically realistic multimodality renal artery phantoms consisting of vessels with varying degrees of stenosis was developed and evaluated using four imaging techniques currently used to detect renal artery stenosis (RAS). The spatial resolution required to visualize vascular geometry and the velocity detection performance required to adequately characterize blood flow in ...

Journal: :Journal of visualized experiments : JoVE 2014
Rick Pleijhuis Arwin Timmermans Johannes De Jong Esther De Boer Vasilis Ntziachristos Gooitzen Van Dam

Inaccuracies in intraoperative tumor localization and evaluation of surgical margin status result in suboptimal outcome of breast-conserving surgery (BCS). Optical imaging, in particular near-infrared fluorescence (NIRF) imaging, might reduce the frequency of positive surgical margins following BCS by providing the surgeon with a tool for pre- and intraoperative tumor localization in real-time....

Journal: :Indonesian Journal of Electrical Engineering and Computer Science 2022

Accurate measurement of spatial resolution in terms modulation transfer function (MTF) is essential computed tomography (CT) images. The purpose this study was to developed a computational phantom that can be used evaluate the effect noise on MTF CT Our phantoms for measuring were with MATLAB software. image blurred by point spread certain standard deviation. Subsequently, different levels adde...

2013
Jing Zou Xiao-Dong Hu Hanyu Lv Xiaotang Hu

The effects of calibration phantoms on the correction results of the empirical artifacts correction method (ECCU) for the case of tube modulation were investigated. To improve the validity of the ECCU method, the effect of the geometry parameter of a typical single-material calibration phantom (water calibration phantom) on the ECCU algorithm was investigated. Dual-material calibration phantoms...

2016
Young Hoon Kim

With the growing use of ultrasound for pain management, we are interested in how to teach and practice ultrasound-guided procedures. Ethically, we should not insert a needle in a patient until after much practice on a phantom. Several types of phantoms have been introduced for ultrasound training, including water, agar/gelatin, elastomeric rubber, and meat phantoms and cadavers. The ideal phant...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید