نتایج جستجو برای: gadolinium

تعداد نتایج: 11285  

Journal: :Investigative radiology 2017
Val M Runge

For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable gadolinium-based contrast agents was identified, nephrogenic systemic fibrosi...

Journal: :AJNR. American journal of neuroradiology 2014
J B M Warntjes A Tisell A-M Landtblom P Lundberg

BACKGROUND AND PURPOSE The administration of gadolinium contrast agent is a common part of MR imaging examinations in patients with MS. The presence of gadolinium may affect the outcome of automated tissue classification. The purpose of this study was to investigate the effects of the presence of gadolinium on the automatic segmentation in patients with MS by using the synthetic tissue-mapping ...

Journal: :AJNR. American journal of neuroradiology 2015
A Crombé M Saranathan A Ruet M Durieux E de Roquefeuil J C Ouallet B Brochet V Dousset T Tourdias

BACKGROUND AND PURPOSE In multiple sclerosis, gadolinium enhancement is used to classify lesions as active. Regarding the need for a standardized and accurate method for detection of multiple sclerosis activity, we compared 2D-spin-echo with 3D-gradient-echo T1WI for the detection of gadolinium-enhancing MS lesions. MATERIALS AND METHODS Fifty-eight patients with MS were prospectively imaged ...

2011
Hassan Ali Zamani

A PVC-membrane ion-selective electrode was constructed for quantitative monitoring of gadolinium(III) ion based on 3-methyl-1H-1,2,4-triazole-5-ylhydrosufide (MTY) as an ion carrier. The electrode performance includes a Nernstian slope of 19.8 ± 0.4 mV per decade across a wide concentration range between 1.0 × 10 and 1.0 × 10 M and a detection limit of 7.3 × 10 M. The best performance was obtai...

Journal: :Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association 2006
Ihsan Ergün Kenan Keven Irfan Uruç Yakup Ekmekçi Basol Canbakan Ilhan Erden Oktay Karatan

BACKGROUND Although there is a well-documented risk of acute renal failure (ARF) with the iodinated contrast agents, intravenous gadolinium-based contrast agents are considered non-nephrotoxic and have been widely used for magnetic resonance imaging (MRI). However, debate continues regarding the safety issue of gadolinium, especially in patients with kidney failure. Therefore, we aimed to evalu...

Journal: :European heart journal cardiovascular Imaging 2013
Joey F A Ubachs Henrik Engblom Sasha Koul Mikael Kanski Patrik Andersson Jesper van der Pals Marcus Carlsson David Erlinge Håkan Arheden

AIMS Determination of the myocardium at risk (MaR) and final infarct size by cardiac magnetic resonance imaging (CMR) enables calculation of salvaged myocardium in acute infarction. T2-weighted imaging is performed prior to the administration of gadolinium, since gadolinium affects T2 tissue properties. This is, however, difficult in an ex vivo model since gadolinium must be administered for de...

2016
Pedro Ramos-Cabrer Francois Fay Brenda L. Sanchez-Gaytan Jun Tang José Castillo Zahi A. Fayad Willem J. M. Mulder

High-density lipoprotein (HDL) nanoparticles doped with gadolinium lipids can be used as magnetic resonance imaging diagnostic agents for atherosclerosis. In this study, HDL nanoparticles with different molar fractions of gadolinium lipids (0 < xGd-lipids < 0.33) were prepared, and the MR relaxivity values (r1 and r2) for all compositions were measured. Both r1 and r2 parameters reached a maxim...

Journal: :AJNR. American journal of neuroradiology 1987
C Hecht-Leavitt R I Grossman W J Curran J T McGrath D N Biery P M Joseph D F Nelson

Two of six cats receiving small-field, single-dose, brain irradiation of 35 Gy with 6 MeV photons developed brain abnormalities in the irradiated area on MR images at 6 and 8 months, respectively, after treatment. The lesions were of high intensity on T2-weighted images and did not enhance after IV administration of gadolinium-DTPA. An additional lesion in one of these cats displayed high signa...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید