نتایج جستجو برای: exchanger

تعداد نتایج: 12093  

Many studies are performed by researchers about Shell and Tube Heat Exchanger but the Multi-Objective Big Bang-Big Crunch algorithm (MOBBA) technique has never been used in such studies. This paper presents application of Thermal-Economic Multi-Objective Optimization of Shell and Tube Heat Exchanger Using MOBBA. For optimal design of a shell and tube heat exchanger, it was first thermally model...

Journal: :international journal of advanced design and manufacturing technology 0
hamid jahedi amlashi

in this work, a thermal energy storage system was designed and equipped with measuring instruments to study heat transfer characteristics and energy storage and release. in this system, a cubic container which is made of plexiglass was filled with dodecanoic acid as a phase change material. in order to transfer heat to the storage container, a constant temperature heat exchanger was designed an...

Journal: :The American journal of physiology 1999
Choon-Ok Park Xiao-Hui Xiao David G Allen

The role of the Na+/H+exchanger in rat hearts during ischemia and reperfusion was investigated by measurements of intracellular Na+ concentration ([Na+]i) and intracellular and extracellular pH. Under our standard conditions (2-Hz stimulation), 10 min of ischemia caused no significant rise in [Na+]ibut an acidosis of 1.0 pH unit, suggesting that the Na+/H+exchanger was inactive during ischemia....

Journal: :The Journal of biological chemistry 2007
Mireya Gonzalez-Begne Tetsuji Nakamoto Ha-Van Nguyen Andrew K Stewart Seth L Alper James E Melvin

Cl(-) influx across the basolateral membrane is a limiting step in fluid production in exocrine cells and often involves functionally linked Cl(-)/HCO(3)(-) (Ae) and Na(+)/H(+) (Nhe) exchange mechanisms. The dependence of this major Cl(-) uptake pathway on Na(+)/H(+) exchanger expression was examined in the parotid acinar cells of Nhe1(-/-) and Nhe2(-/-) mice, both of which exhibited impaired f...

2014
Andrew Sommers Anthony M. Jacobi A. D. SOMMERS A. M. JACOBI

In air-cooling applications with frost production, heat exchanger performance is often air-side limited, because the two-phase flow of the refrigerant provides excellent heat transfer coefficients, and because designers typically use a large air-side fin spacing for frost tolerance. The large fin spacing prolongs operation of the heat exchanger by mitigating the effect of the accumulating frost...

Journal: :American journal of physiology. Lung cellular and molecular physiology 1998
Yuang-Shuang Liaw Pan-Chyr Yang Chong-Jen Yu Sow-Hsong Kuo Kwen-Tay Luh Yuh-Jeng Lin Mei-Lin Wu

Epidermal growth factor (EGF) stimulates the Na+-H+exchanger, leading to enhanced cell proliferation. In human pleural mesothelial cells (PMCs), the intracellular signaling mechanism mediating the EGF-induced stimulation of the Na+-H+exchanger has not yet been identified. Using a pH-sensitive fluorescent probe, 2',7'-bis(2-carboxyethyl)-5(6)-carboxyfluorescein, to measure changes in intracellul...

2013
Ian Bell Eckhard A. Groll Ian H. Bell

In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing the air-...

2014
Ian H. Bell Eckhard A. Groll

In this study, the air-side pressure drop and heat transfer performance of plate-fin and microchannel coils were tested under clean and fouled conditions. The heat exchangers were tested with two different types of dust, ASHRAE Standard Dust and Arizona Road Test Dust. The ASHRAE dust was found to have a very significant impact on the pressure drop of the microchannel heat exchanger, increasing...

2014
Mustapha Ait Lafkih

In industrial environments, the heat exchanger is a necessary component to any strategy of energy conversion. Much of thermal energy used in industrial processes passes at least one times by a heat exchanger, and methods systems recovering thermal energy. This survey paper tries to presents in a systemic way an sample control of a heat exchanger by comparison between three controllers LQR (line...

Journal: :American journal of physiology. Cell physiology 2004
Olga Chernysh Madalina Condrescu John P Reeves

Allosteric regulation by cytosolic Ca2+ of Na(+)/Ca2+ exchange activity in the Ca2+ efflux mode has received little attention because it has been technically difficult to distinguish between the roles of Ca2+ as allosteric activator and transport substrate. In this study, we used transfected Chinese hamster ovary cells to compare the Ca2+ efflux activities in nontransfected cells and in cells e...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید