Automatic tube current modulation (ATCM) systems are available for all CT manufacturers and are used for the majority of patients. Understanding how the systems work and their influence on patient dose and image quality is important for CT users, in order to gain the most effective use of the systems. In the present study, a new phantom was used for evaluating dose distribution and image qualit...
در طول مدت بستری، برای نوزادان نارس (premature) و یا بیمار بستری در بخش مراقبت های ویژه ی نوزادان (nicu یا neonatal intensive care unit)، تعداد زیادی رادیوگرافی انجام می شود. به دلیل آن که نوزادان اندازه ی کوچکی دارند، در هنگام رادیوگرافی، بخش بزرگی از آناتومی آنان در میدان تابش قرار می گیرد. از طرف دیگر نوزادان، نسبت به پرتو حساس تر از بالغین هستند و خطر سرطان ناشی از تابش در آن ها، 2 تا 3 برا...
Background: Intraoral radiographs are believed to deliver low doses to patients, thus little work has been done in this regards. Considering the increment in the number of patients reporting for the examination and the probability of delayed somatic effects for accumulated low doses of X-irradiation, it is expedient to determine the doses to three critical organs eye, thyroid and parotid that a...
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the sign...
The aim of the study was to design and construct an anatomical and radiological phantom of a neonatal chest for investigating image quality and patient entrance surface dose (ESD). The density, elemental composition, scatter, attenuation, and absorption characteristics of different possible substitute materials were compared to that of neonatal tissues for radiological equivalence. Availability...
TL dosimetry is known as one of the effective dose estimation methods in diagnostic radiology. Cephalometry is used by dentists, oral and maxillofacial surgeons to choose the appropriate treatment. The purpose of this study is to measure the entrance skin dose, and dose to different organs of the patients in cephalometry using TLD-100. The entrance skin, and organ dose were obtained by putting ...
Objective: The current research study aims to calculate entrance surface air kerma for skull, chest, cervical spine, lumbar and pelvic X-ray examinations in interior posterior positions generate a method chest dose reduction decrease radiation risk. Materials Methods: indirect measurement was used the research. tube output measured using RAD-CHECK Plus ionization chamber calculated via applying...
زمینه و هدف: بیشترین پرتوگیری مردم از منابع پرتو ساخت بشر، ناشی از آزمایش های تشخیصی با پرتو ایکس می باشد که این امر به دلیل اجتناب ناپذیر بودن تشخیص با پرتوهای ایکس و همچنین تعداد آنها در میان افراد جامعه می باشد. برای عملی کردن برنامه کاهش دوز جذبی بیماران و در عین حال افزایش کیفیت تصاویر رادیوگرافی در بیمارستان های وابسته به دانشگاه علوم پزشکی استان دوز سطحی بیماران و نیز دوز مؤثر آنان انداز...
Background: Anode heel effect refers to reduction of radiation intensity in the anode side of X-ray tube. This variation in radiation intensity across the anode-cathode of X-ray tube can be benefited for decrease radiation exposure in some radiological examinations. The aim of this study was to evaluate the effect of anode heel orientation on the radiation dose received by the testes in male pa...