2013
Ken Sexton Jennifer J. Salinas Thomas J. McDonald Rose M. Z. Gowen Rebecca P. Miller Joseph B. McCormick Susan P. Fisher-Hoch

Biomarkers of organochlorine pesticides were measured in both venous and umbilical cord blood from 35 pregnant Hispanic women living in Brownsville, Texas, USA. Gas chromatography with an electron capture detector was used to analyze specimens for 30 individual pesticides or their metabolites. Results indicate that blood concentrations were relatively low for most individual compounds, but that...

Journal: :Clinical chemistry 1983
S R Hamann R G McAllister

In this method for measuring nifedipine, a calcium-channel inhibitor now widely used in the treatment of cardiovascular disease, the drug is extracted from plasma under basic conditions into toluene, and an aliquot of the extract is injected directly into a gas chromatograph equipped with an OV-101 column and an electron-capture detector. The standard curve is linear between 1 and 100 microgram...

Journal: :British journal of anaesthesia 1973
M M Atallah I C Geddes

The metabolism of halothane during and after anaesthesia was studied in eight patients of different age and body weight by estimating the concentration of halothane and one of its metabolites (bromide) in the blood. A gas chromatograph with an electron capture detector was used to estimate halothane, while blood bromide levels were measured by neutron activation analysis. There was an initial b...

Journal: :Plant physiology 1987
S Y Wang T Sun Z L Ji M Faust

Abscisic acid (ABA) was quantitated by enzyme-linked immunosorbent assay (ELISA) in water-stressed leaves from control apple seedlings, and also from apple seedlings treated for 28 days with paclobutrazol ([2RS, 3RS]-1-[4-chlorophenyl]-4,4-dimethyl-2-[1,2,4-triazol-1-yl] pentan-3-ol). The ELISA quantitative estimates were also validated by gas chromatography-electron capture detector and lettuc...

Journal: :Clinical chemistry 1982
J F Nash R J Bopp R H Carmichael K Z Farid L Lemberger

This gas-chromatographic method for assay of fluoxetine and norfluoxetine in human plasma involves extraction of the drugs and use of a 63Ni electron-capture detector. The linear range of detection is 25 to 800 micrograms/L for each drug. Overall precision (CV) in the concentration range of 10 to 100 micrograms/L for both drugs was approximately 10%. Accuracy (relative error) in the same concen...