2017
Emily K. Brooks Mark T. Ehrensberger

Three Mg alloys, Mg-1.34% Ca-3% Zn (MCZ), Mg-1.34% Ca-3% Zn-0.2% Sr (MCZS), and Mg-2% Sr (MS), were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM) of...

2015
Jörn Reinders Robert Sonntag Leo Vot Christian Gibney Moritz Nowack Jan Philippe Kretzer

Resumption of daily living activities is a basic expectation for patients provided with total knee replacements. However, there is a lack of knowledge regarding the impact of different activities on the wear performance. In this study the wear performance under application of different daily activities has been analyzed. In vivo load data for walking, walking downstairs/upstairs, sitting down/s...

Journal: :Medical science monitor : international medical journal of experimental and clinical research 2009
J Philippe Kretzer Eike Jakubowitz Kerstin Hofmann Christian Heisel Eva Lietz

BACKGROUND Knee wear simulator studies are performed to evaluate the wear behavior of implants. These wear studies simulate in vivo situations as closely as possible. Simulation of the human gait cycle is often carried out continuously according to international standards. However, implants are not loaded continuously in vivo, so it might be advisable to implement resting periods in which no mo...

Wear is a complicated phenomenon caused by the relative movement of two contacting surfaces compressed together by a normal force. Prediction of the wear, in most cases, requires various experiments and microstructural characterization of the contacting surfaces. Mathematical models based on physical concepts could provide considerable help in understanding the physical behavior and hence the p...

Wear is a complicated phenomenon caused by the relative movement of two contacting surfaces compressed together by a normal force. Prediction of the wear, in most cases, requires various experiments and microstructural characterization of the contacting surfaces. Mathematical models based on physical concepts could provide considerable help in understanding the physical behavior and hence the p...

2007
Robert J K Wood

This paper reviews the available literature relating to the emerging research into the performance of coatings under combined wear and corrosion conditions. Understanding how coatings perform under these tribo-corrosion conditions is essential if the service life of equipment is to be predicted and to allow service life to be extended. Therefore, the tribo-corrosion performance of coatings depo...

2008
L. V. Wilches J. A. Uribe A. Toro

Two tribological pairs used for artificial joints were studied. Wear tests were performed in a pin-on-disc type machine modified to allow lubrication ith bovine serum. The pins were made of either AISI F138 stainless steel or ASTM F136 titanium alloy, while the discs were manufactured with ltra-high molecular weight polyethylene (UHMWPE). The tested pairs were ASTM F138 stainless steel–UHMWPE a...

Journal: :journal of advanced materials and processing 0
mehdi manouchehrian south tehran branch, islamic azad university, tehran, iran

tan films with different n2 partial pressure were deposited on 304 stainless steel using the magnetron sputtering method. the effect of gas pressure on the mechanical property, morphology and phase structure of the films is investigated by x-ray diffraction (xrd), atomic force microscopy (afm), microhardness testing, friction coefficient measurements, and wear mechanism study. the xrd results c...

2017
Tomofumi Sawada Christine Schille Atif Almadani Jürgen Geis-Gerstorfer

Experimental cast titanium alloys containing 20 mass% chromium (Ti-20Cr) show preferable mechanical properties and a good corrosion resistance. This study evaluated the fretting corrosion behavior of Ti-20Cr. Ti-20Cr (n = 4) and commercially pure titanium (CP-Ti, n = 6) disk specimens were used. The fretting corrosion test was performed by electrochemical corrosion at 0.3 V in 0.9% saline solut...

2001
K. P. JUDMANN

INTRODUCTION The development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses has led to an increasing demand for testing and verification. This includes tests and research regarding bio-compatibility, static load bearing capacity of the prostheses as well as tribological investigations. Since it has been found that wear debris play a dominant rol...