نتایج جستجو برای: ebt3 radiochromic film

تعداد نتایج: 91084  

2016
Ning Wen Siming Lu Jinkoo Kim Yujiao Qin Yimei Huang Bo Zhao Chang Liu Indrin J Chetty

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

Journal: :Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics 2008
Martin J Butson Tsang Cheung Peter K N Yu Sian Price Michael Bailey

Accurate measurement and knowledge of dose delivered under eye shield during superficial X-ray radiotherapy is required for patient peripheral dose assessment. Critical structures can include the cornea, lens and retina. Measurement of dose under eye shields has been historically performed with Thermoluminescent Dosimeters (TLD's) due to their small size and design. Restrictions include the ene...

2016
Toshizo Katsuda Rumi Gotanda Tatsuhiro Gotanda Takuya Akagawa Nobuyoshi Tanki Tadao Kuwano Kouichi Yabunaka

This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the d...

2013
Steven R. Jackson Salahuddin Ahmad Yida Hu Chun Ruan

This work has been conducted to demonstrate a procedure for using a Konica Minolta computed radiography (CR) system for the measurement of computed tomography (CT) radiation profile width, and to compare this method with conventional and GAFCHROMIC XR-QA2 film measurements. The exposure and processing conditions of a Konica Minolta CR reader system were characterized to establish the relationsh...

2015
Fasihah Hanum Yusof Ngie Min Ung Jeannie Hsiu Ding Wong Wei Loong Jong Vannyat Ath Vincent Chee Ee Phua Siew Ping Heng Kwan Hoong Ng Chih-Hsin Tang

This study was carried out to investigate the suitability of using the optically stimulated luminescence dosimeter (OSLD) in measuring surface dose during radiotherapy. The water equivalent depth (WED) of the OSLD was first determined by comparing the surface dose measured using the OSLD with the percentage depth dose at the buildup region measured using a Markus ionization chamber. Surface dos...

Journal: :Physics in medicine and biology 2004
Tsang Cheung Martin J Butson Peter K N Yu

This short note investigates the energy response characteristics of a relatively new high sensitivity radiochromic film (XR type T) and compares it to other radiochromic and radiographic films and thermoluminescent dosimeters. Results show that the energy response of the new XR type T film is relatively large over the range of therapeutic energies from 50 kVp superficial x-ray treatment to 18 M...

Journal: :Physics in medicine and biology 2001
T Cheung M J Butso P K Yu

This note investigates the increase of the sensitivity of radiochromic film by layering the film together. Investigations with up to five layers of radiochromic film placed together as a single dosimeter have allowed accurate two-dimensional dosimetry at low radiotherapy doses. The sensitivity of the response of the layered film increases with the number of layers, with the five-layer dosimeter...

Journal: :Physics in Medicine and Biology 2002

Journal: :Physics in Medicine and Biology 2000

Journal: :Physics in Medicine and Biology 2015

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید