نتایج جستجو برای: dynamic hip screw
تعداد نتایج: 481208 فیلتر نتایج به سال:
A case of arterial rupture of the profunda femoris arterial branches, following dynamic hip screw (DHS) fixation for an intertrochanteric femoral fracture, is presented. Bleeding is controlled by coil embolization, but, later on, the patient underwent orthopedic material removal due to an infection of a large femoral hematoma.
سابقه و هدف: با توجه به روند رو به افزایش شکستگی ناحیهی اینترتروکانتریک و استفاده از dynamic hip screw (DHS) به عنوان درمان ارجح برای این نوع شکستگیها، روش اکسترنال فیکساسیون میتواند نتایج قابل مقایسهای با این درمان داشته باشد. علاوه بر این، چون روش اکسترنال فیکساسیون کمتر تهاجمی است، انتظار میرود موربیدیتی کمتری ایجاد شود. از آنجا که تا کنون در ایران مطالعهای در این زمینه انجام نشده، در این...
It is a huge stress that remaining screws in the bone cannot be seen from the bone surface to remove the screw with fluoroscopy. Sometimes 2D fluoroscopy technique is difficult to remove hidden screws or metal pieces. To seek the hidden screw, skin incision, cortical bone loss and weakness of the long bone shaft will be increased. No case of total hip arthroplasty with screw removing assisted o...
We report a case of an above-knee amputee who underwent dynamic hip screw fixation for a proximal femoral fracture and then open reduction and internal fixation a few years later for a further femoral fracture in the same stump. The patient had a good outcome. We aim to discuss the challenges in decision making, surgical technique and potential complications for the patient.
We compared, under laboratory conditions, the resistance to cutting out of the AO dynamic hip screw and the Pugh sliding nail. The mean load at cut out, adjusted for bone strength, was 70% greater for the Pugh sliding nail. The reasons for this difference are discussed.
We describe the use of non-invasive positive pressure ventilation combined with spinal anaesthesia to allow the insertion of a dynamic hip screw in an obese patient with advanced chronic obstructive pulmonary disease. The technique avoided the hazards of intubation and general anaesthesia in this high-risk patient.
We present a potential indication of a short-stemmed femoral component in a patient with multiple comorbidities presenting with hip posttraumatic osteoarthritis and a long dynamic condylar screw osteosynthesis plate. Removal of the plate and implantation of a long stem would have been related to a much longer operative time and potential local or systemic complications.
The authors report a rare per-operative complication of intra-pelvic migration of dynamic hip screw, during osteosynthesis of an inter-trochanteric fracture. Possible reasons of migration are analyzed along with the importance of careful execution of the surgical technique to avoid such iatrogenic complications and medico-legal implications.
Objective: The aim of the study was to evaluate surgical characteristics proximal femoral nail and dynamic hip screw stabilisation for intertrochanteric fractures. Methods: After ethical approval from institutional review board, this randomized controlled trial, conducted at Orthopaedic Department, Jinnah Post Graduate Medical Centre, Karachi, 29th July 2018 28th January 2019 through non-probab...