Journal: :Medical physics 2009
Slobodan Devic Nada Tomic Christopher G Soares Ervin B Podgorsak

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the...

Journal: :Radiation protection dosimetry 2016
Filip Vanhavere

This special issue of the journal Radiation Protection Dosimetry is dedicated to the Proceedings of the International Conference on Individual Monitoring of Ionising Radiation (IM2015) held in Bruges, Belgium, from 20 to 24 April 2015. IM2015 was the fifth of a series of conferences dealing with individual monitoring. This conference series is initiated by EURADOS, the European Radiation Dosime...

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 2001
J C Sisson J E Carey

UNLABELLED In some patients with well-differentiated thyroid carcinoma, dosimetry is necessary to avoid toxicity from therapy and to guide prescription of the administered activity of radioiodine. METHODS The presentations and courses of 2 patients exemplify the points. In the second patient, the clues to the need for dosimetry were the large size of the tumor and high circulating levels of t...

2010
Savino Cilla Andrea Fidanzio Francesca Greco Domenico Sabatino Aniello Russo Laura Gargiulo Luigi Azario Angelo Piermattei

In-vivo dosimetry techniques are currently being applied only by a few Centers because they require time-consuming implementation measurements, and workload for detector positioning and data analysis. The transit in-vivo dosimetry performed by the electronic portal imaging device (EPID) avoids the problem of solid-state detector positioning on the patient. Moreover, the dosimetric characterizat...

Journal: :Journal of physics. Conference series 2006
Mark Oldham

The need for an accurate, practical, low-cost 3D dosimetry system is becoming ever more critical as modern dose delivery techniques increase in complexity and sophistication. A recent report from the Radiological Physics Center (RPC) (1), revealed that 38% of institutions failed the head-and-neck IMRT phantom credentialing test at the first attempt. This was despite generous passing criteria (w...

Journal: :The British journal of dermatology 2002
D K Taylor A V Anstey A J Coleman B L Diffey P M Farr J Ferguson S Ibbotson K Langmack J J Lloyd P McCann C J Martin H Du P Menagé H Moseley G Murphy S D Pye L E Rhodes S Rogers

This report examines the dosimetry of ultraviolet (UV) radiation applied to dermatological treatments, and considers the definition of the radiation quantities and their measurement. Guidelines are offered for preferred measurement techniques and standard methods of dosimetry. The recommendations have been graded according to the American Joint Committee on Cancer classification of strength of ...

Journal: :European Physical Journal Plus 2021

Abstract Ionizing radiation is ubiquitous in the environment. Its source can be natural, such as radioactive materials present soil and cosmic rays, or artificial, fuel for nuclear power plants. Overexposure to ionizing may damage living tissue could cause severe health problems (i.e., mutations, sickness, cancer, death). Cytogenetic bio-dosimetry has great advantage take into account inter-ind...

2017
Anders R. Beierholm Claus F. Behrens Patrik Sibolt Marianne C. Aznar Jakob B. Thomsen Claus E. Andersen

max. 2000 char.): A comparison of dosimetry methods at different clinics can be used as a means to uncover systematic uncertainties in radiotherapy. To assess the current status of reference dosimetry and small-field dosimetry in clinical practice, a collaborative comparison study involving several dosimetry methods was performed by DTU Nutech at six Danish clinics. The first part of the interc...

Journal: :Medical physics 2012
Slobodan Devic Nada Tomic Saad Aldelaijan Francois Deblois Jan Seuntjens Maria F Chan Dave Lewis

PURPOSE Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present resu...

2007
avid F. Lewis

The Vidar use with r designed t work in th compared reported f resolution scattering artifact of eliminated the Red L the availa scanner y linear acc INTERNATIONAL SPECIALTY PRODUCTS 1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000 rmance of the Vidar Red LED Dosimetry Pro AdvantageTM: r optimized for use with GAFCHROMIC EBT Dosimetry Film. avid F. Lewis, Ph.D., Senior Director, Advanced Materi...