نتایج جستجو برای: dose to oars

تعداد نتایج: 10675840  

2018
Seong-Hee Kang Siyong Kim Dong-Su Kim Tae-Ho Kim So-Hyun Park Dong-Seok Shin Kyeong-Hyeon Kim Min-Seok Cho YeonSil Kim Tae Suk Suh

Background To propose an effective and simple cost value function to determine an optimal respiratory phase for lung treatment using either respiratory gating or breath-hold technique. Results The optimized phase was obtained at a phase close to end inhalation in 11 out of 15 patients. For the rest of patients, the optimized phase was obtained at a phase close to end exhalation indicating tha...

2016
Markus Stoll Eva Maria Stoiber Sarah Grimm Jürgen Debus Rolf Bendl Kristina Giske

PURPOSE Intensity modulated radiation therapy (IMRT) of head and neck tumors allows a precise conformation of the high-dose region to clinical target volumes (CTVs) while respecting dose limits to organs a risk (OARs). Accurate patient setup reduces translational and rotational deviations between therapy planning and therapy delivery days. However, uncertainties in the shape of the CTV and OARs...

2016
Dong Soo Lee Joong-Yeol Woo Jun Won Kim Jinsil Seong

PURPOSE This study aimed to evaluate whether the deformable image registration (DIR) method is clinically applicable to the safe delivery of re-irradiation in hepatocellular carcinoma (HCC). MATERIALS AND METHODS Between August 2010 and March 2012, 12 eligible HCC patients received re-irradiation using helical tomotherapy. The median total prescribed radiation doses at first irradiation and r...

Journal: :Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology 2012
Steven F Petit Binbin Wu Michael Kazhdan André Dekker Patricio Simari Rachit Kumar Russel Taylor Joseph M Herman Todd McNutt

PURPOSE To develop a model to assess the quality of an IMRT treatment plan using data of prior patients with pancreatic adenocarcinoma. METHODS The dose to an organ at risk (OAR) depends in large part on its orientation and distance to the planning target volume (PTV). A database of 33 previously treated patients with pancreatic cancer was queried to find patients with less favorable PTV-OAR ...

2014
Mehee Choi Tamer Refaat Malisa S Lester Ian Bacchus Alfred W Rademaker Bharat B Mittal

OBJECTIVES Limiting radiation dose to the larynx can diminish effects of laryngeal dysfunction. However, no clear guidelines exist for defining the larynx and its substructures consistently on cross-sectional imaging. This study presents computed tomography (CT)- and magnetic resonance imaging (MRI)-based guidelines for contouring laryngeal organs-at-risk (OARs). MATERIALS AND METHODS Standar...

2017
Xin Wang Yuan Tian Yuan Tang Zhi-Hui Hu Jia-Jia Zhang Gui-Shan Fu Pan Ma Hua Ren Tao Zhang Ning Li Wen-Yang Liu Hui Fang Ye-Xiong Li Jing Jin

PURPOSE To compare dosimetric parameters of intensity-modulated radiotherapy (IMRT), volumetric-modulated arc therapy (VMAT) and tomotherapy (TOMO) in the adjuvant treatment of gastroesophageal junction (GEJ)/stomach cancer. The planning goal was to maintain high target coverage while keeping the dose to the bowel and bone marrow (BM) as low as possible. MATERIALS AND METHODS After curative s...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2014
Nima Nabavizadeh Anna O Simeonova Joseph G Waller Jeanna L Romer Debra L Monaco David A Elliott James A Tanyi Martin Fuss Charles R Thomas John M Holland

Volumetric-modulated arc radiotherapy (VMAT) is an iteration of intensity-modulated radiotherapy (IMRT), both of which deliver highly conformal dose distributions. Studies have shown the superiority of VMAT and IMRT in comparison with 3-dimensional conformal radiotherapy (3D-CRT) in planning target volume (PTV) coverage and organs-at-risk (OARs) sparing. This is the first study examining the be...

2008
Bodo Reitz Moyed Miften

Reducing the treatment time for IMRT patients is highly desirable. The objective of this work was to evaluate the new clinical Siemens KonRad inverse treatment planning system (TPS) and compare it to the CMS XiO TPS with special emphasis on the segmentation efficiency. For head and neck, liver and prostate cancer patients, step-and-shoot IMRT plans were designed using both CMS XiO and Siemens K...

2013
Chi-Ta Lin An-Cheng Shiau Hui-Ju Tien Hsin-Pei Yeh Pei-Wei Shueng Chen-Hsi Hsieh

An anthropomorphic phantom was used to investigate a treatment technique and analyze the dose distributions for helical irradiation of the total skin (HITS) by helical tomotherapy (HT). Hypothetical bolus of thicknesses of 0, 10, and 15 mm was added around the phantom body to account for the dose homogeneity and setup uncertainty. A central core structure was assigned as a "complete block" to f...

2015
Dirk Van Gestel Geert De Kerf Kristien Wouters Wouter Crijns Jan B. Vermorken Vincent Gregoire Dirk Verellen

BACKGROUND The last few years, in radiotherapy there has been a growing focus on speed of treatment delivery (largely driven by economical and commercial interests). This study investigates the influence of treatment time on plan quality for helical tomotherapy (HT), using delivery times with Volumetric Modulated Arc Therapy (VMAT; Rapid Arc [RA]) as reference. METHODS In a previous study, do...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید