نتایج جستجو برای: discrete subaortic stenosis

تعداد نتایج: 224466  

Journal: :Physical review letters 2002
A Trombettoni A Smerzi A R Bishop

We study the discrete nonlinear Schrödinger equation (DNLS) in an annular geometry with on-site defects. The dynamics of a traveling plane-wave maps onto an effective nonrigid pendulum Hamiltonian. The different regimes include the complete reflection and refocusing of the initial wave, solitonic structures, and a superfluid state. In the superfluid regime, which occurs above a critical value o...

Journal: :Applied optics 2010
Evgenij Zubko Dmitry Petrov Yevgen Grynko Yuriy Shkuratov Hajime Okamoto Karri Muinonen Timo Nousiainen Hiroshi Kimura Tetsuo Yamamoto Gorden Videen

There are two widely accepted restrictions on the application of the discrete dipole approximation (DDA) in the study of light scattering by particles comparable to the wavelength: (1) when considering dielectric particles, the size of the cells must satisfy the condition kd|m|<0.5, where k is the wavenumber, d is the size of the cells, and m is the complex refractive index of the constituent m...

2004
Ronald Jones Tristrom Cooke Nicholas J. Redding Nicholas Redding

This report discusses the implementation of the Radon transform in the Analysts’ Detection Support System (ADSS) environment using non-equispaced Discrete Fourier Transforms (DFTs). It provides an analysis and experimental results for discretisation error and the use of matched filtering to enhance peaks in the transform. APPROVED FOR PUBLIC RELEASE

2016
Abdessalem Ben Abdelali Ichraf Chatti Marwa Hannachi Abdellatif Mtibaa

This paper presents a hardware module design for the forward Binary Discrete Cosine Transform (BinDCT) and its implementation on a field programmable gate array device. Different architectures of the BinDCT module were explored to ensure the maximum efficiency. The elaboration of these architectures included architectural design, timing and pipeline analysis, hardware description language model...

Journal: :Journal of biomedical optics 2013
Lei Bi Ping Yang

The invariant imbedding T-matrix method (II-TM) is employed to simulate the optical properties of normal biconcave and deformed red blood cells (RBCs). The phase matrix elements of a RBC model computed with the II-TM are compared with their counterparts computed with the discrete-dipole approximation (DDA) method. As expected, the DDA results approach the II-TM results with an increase in the n...

Journal: :Chest 1981
Y L Doi R L Bishop T Sugiura D H Spodick

Echocardiographic examination in a patient with primary pulmonary hypertension demonstrated midsystolic closure of the aortic valve, which has often been described in hypertrophic cardiomyopathy with or without obstruction, in discrete subaortic stenosis, and in ruptured aneurysm of the right coronary sinus of Valsalva. A possible mechanism for this finding in primary pulmonary hypertension and...

Journal: :British heart journal 1980
J Candell-Riera H G del Castillo J Rius

An early systolic closure of the aortic valve was recorded in the echocardiogram in two patients with aortic root dissection. This sign, initially described in discrete subaortic stenosis and occasionally observed in mitral regurgitation and interventricular septal defect, has not so far been described in dissecting aneurysm of the aorta.

Journal: :Sklifosovsky Journal "Emergency Medical Care" 2017

2005
T. Tony Cai

One-sided con&dence intervals in the binomial, negative binomial, and Poisson distributions are considered. It is shown that the standard Wald interval su4ers from a serious systematic bias in the coverage and so does the one-sided score interval. Alternative con&dence intervals with better performance are considered. The coverage and length properties of the con&dence intervals are compared th...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید