نتایج جستجو برای: digital tomography

تعداد نتایج: 486419  

2008
Frank HEROLD

X-Rays are used as reliable technique for today’s quality assurance of safety critical parts, for example in the automotive or in the aerospace industry. Radiography systems are used to ensure a high throughput in the field of hundred percent testing of a batch. In such systems digital images are acquired by using either flat-panel detectors with a high dynamic range or image intensifiers inclu...

Journal: :Applied optics 2005
Pia Massatsch Florian Charrière Etienne Cuche Pierre Marquet Christian D Depeursinge

We show that digital holography can be combined easily with optical coherence tomography approach. Varying the reference path length is the means used to acquire a series of holograms at different depths, providing after reconstruction images of slices at different depths in the specimen thanks to the short-coherence length of light source. A metallic object, covered by a 150-microm-thick onion...

2018
Alessandra Giuliani Serena Mazzoni Alessandra Ruggiu Barbara Canciani Ranieri Cancedda Sara Tavella

Bone remodeling process consists in a slow building phase and in faster resorption with the objective to maintain a functional skeleton locomotion to counteract the Earth gravity. Thus, during spaceflights, the skeleton does not act against gravity, with a rapid decrease of bone mass and density, favoring bone fracture. Several studies approached the problem by imaging the bone architecture and...

Journal: :Optics letters 2012
Emilie Benoit a la Guillaume Salma Farahi Emmanuel Bossy Michel Gross Francois Ramaz

Acousto-optical coherence tomography (AOCT) consists in using random phase jumps on ultrasound and light to achieve a millimeter resolution when imaging thick scattering media. We combined this technique with heterodyne off-axis digital holography. Two-dimensional images of absorbing objects embedded in scattering phantoms are obtained with a good signal-to-noise ratio. We study the impact of t...

Journal: :Optics letters 2006
Florian Charrière Anca Marian Frédéric Montfort Jonas Kuehn Tristan Colomb Etienne Cuche Pierre Marquet Christian Depeursinge

For what we believe to be the first time, digital holographic microscopy is applied to perform optical diffraction tomography of a pollen grain. Transmission phase images with nanometric axial accuracy are numerically reconstructed from holograms acquired for different orientations of the rotating sample; then the three-dimensional refractive index spatial distribution is computed by inverse ra...

2008
M C Potcoava M K Kim

We present results of imaging experiments using digital interference holography (DIH). Calibration experiments using a resolution target demonstrate an improvement of signal-to-noise ratio (SNR) with increasing number of holograms consistent with theoretical prediction. Imaging experiments on retinal tissue reveal the topography of blood vessels as well as the optical thickness profile of the r...

Journal: :Ortopedia, traumatologia, rehabilitacja 2009
Kazimierz Rapała Sławomir Chaberek Aleksandra Truszczyńska Stanisław Łukawski Piotr Walczak

BACKGROUND The study of lumbar spine pathology requires adequate preparation and knowledge of the normal structure of this part of the spine. The main goal of the study was to assess spinal canal morphology with computed tomography. The sagittal and interpedicular dimensions and surface area were considered the most important measurements. An additional goal was to assess the shape of the spina...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید