background: this study aimed to investigate the pedicle dimension and angulation in cervicothoracic junction (ctj) using the findings of computed tomographic (ct) to help accurate insertion of pedicular screw. methods: forty three patients with high quality ct images of ctj were evaluated. pedicle width (pw), pedicle height (ph), pedicle axis length (pal), transverse angle (ta) and sagittal ang...
OBJECTIVES To evaluate the efficacy of osteosynthesis on femoral neck fractures using two instead of three screws. METHODS Thirty-nine fractures were retrospectively evaluated, divided into groups in which two screws were used in parallel (n = 28) or three screws (n =11) in an inverted triangle configuration (in accordance with the AO technique). The patients were then followed up until reach...
OBJECTIVE To present the accuracy and safety of cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy. METHODS We retrospectively reviewed 12 consecutive patients. A total of 104 subaxial cervical pedicle screws in 12 patients had been inserted. We also assessed the clinical and radiological outcomes and analyzed the direction and grade...
This in vitro investigation compared the effect of using either gold or titanium retaining screws on preload in the dental implant- abutment complex. Inadequate preload can result in screw loosening, whilst fracture may occur if preload is excessive. These are the most commonly reported complications in implant-retained prostheses, and result in unscheduled, costly and time-consuming visits for...
Twenty-seven paired human cadaveric knee specimens were used to determine the effect of surgical technique and various interference screw parameters on the pullout strength of patellar tendon femoral bone blocks. The study compared the fixation strength of endoscopically inserted and conventional "rear-entry" screws of different diameters and lengths. In all tests the most frequent mode of fail...
The incorporation of tendon graft into bone tunnel is one of the most challenging clinical issues in anterior cruciate ligament (ACL) reconstruction. As a biodegradable metal, Mg has appropriate mechanical strength and osteoinductive effects, thus may be a promising alternative to commercialized products used for graft fixation. Therefore, it was hypothesized that Mg based interference screws w...
background: reusing orthodontic mini-screws would reduce treatment cost and lead to more use of mini-screws and improvement of orthodontic treatments. this study has assessed the effects of reprocessing and reusing the titanium mini-screws on their maximum insertion, removal and fracture torque (ft). materials and methods: in this experimental study, 20 titanium mini-screws (1.6-mm × 8-mm) were...
OBJECT In 2009, Santoni et al. reported cortical bone trajectory (CBT) as a method of inserting pedicle screws to obtain more solid fixation, and proposed the use of cortical trajectory screws with a more closely placed thread (cortical screws) for CBT. Since the entry trajectory in CBT differs from that in the traditional trajectory, it is unclear whether the increased strength derives from th...
In this study, we prepared nano-hydroxyapatite/polyamide 66/glass fibre (n-HA/PA66/GF) bioactive bone screws. The microstructure, morphology and coating of the screws were characterised, and the adhesion, proliferation and viability of MC3T3-E1 cells on n-HA/PA66/GF scaffolds were determined using scanning electron microscope, CCK-8 assays and cellular immunofluorescence analysis. The results c...