نتایج جستجو برای: cp titanium

تعداد نتایج: 70043  

Journal: :Brazilian dental journal 2006
Sicknan Soares da Rocha Gelson Luis Adabo Guilherme Elias Pessanha Henriques Mauro Antônio de Arruda Nóbilo

The purpose of this study was to evaluate the effect of heat treatments on the Vickers hardness of commercially pure titanium and Ti-6Al-4V cast alloys. Six-millimeter-diameter cylindrical specimens were cast in a Rematitan System. Commercially pure titanium and Ti-6Al-4V alloy specimens were randomly assigned to 3 groups (n=10) that received the following heat treatments: control (no heat trea...

Journal: :Brazilian oral research 2005
Wagner Sotero Fragoso Guilherme Elias Pessanha Henriques Edwin Fernando Ruiz Contreras Marcelo Ferraz Mesquita

Commercially pure titanium (CP Ti) has been widely applied to fabricate cast devices because of its favorable properties. However, the mold temperature recommended for the manufacture of casts has been considered relatively low, causing inadequate castability and poor marginal fit of cast crowns. This study evaluated and compared the influence of mold temperature (430 degrees C--as control, 550...

Journal: :Brazilian dental journal 2008
Renata Cristina Silveira Rodrigues Ana Paula Macedo Erica Miranda de Torres Maria da Glória Chiarello de Mattos Ricardo Faria Ribeiro

The objective of this study was to evaluate the retention force of T-bar clasps made from commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) alloy by the insertion/removal test simulating 5 years use. Thirty-six frameworks were cast from CP Ti (n=18) and Co-Cr alloy (n=18) with identical prefabricated patterns on refractory casts from a distal extension mandibular hemi-arch segment....

Journal: :Coatings 2023

The structure changes, microstructure evolution, and mechanical properties during Powder Metallurgy (PM) through High Vacuum Sintering of a Ti-TiH2 matrix reinforced with Titanium Diboride (TiB2) particles were investigated. Composites fabricated at 850, 1100, 1300 °C. strategy for the fabrication process was to use PM route employing titanium hydride (TiH2) reduce consumption Commercially Pure...

Journal: :Additive manufacturing 2022

Titanium lattice structures have found a wide range of lightweight applications. However, made from the commonly-used commercially pure titanium (CP−Ti) and Ti−6Al−4V exhibit either low strength or post-yielding softening/collapse under uniaxial compression, making them less attractive to energy absorbing In present work, series gyroid been designed additively manufactured by laser powder bed f...

2010
Renata Cristina Silveira RODRIGUES Adriana Claudia Lapria FARIA Iara Augusta ORSI Maria da Gloria Chiarello de MATTOS Ana Paula MACEDO Ricardo Faria RIBEIRO

UNLABELLED The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. OBJECTIVE This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clas...

Journal: :Bioinorganic Chemistry and Applications 2005
A. K. Srivastava O. P. Pandey S. K. Sengupta

The reactions of bis(cyclopentadienyl)titanium(IV) dichloride with Schiff bases derived by condensing 2- amino-5-phenyl-1,3,4-thiadiazole with benzaldehyde (SPT), 4-nitrobenzaldehyde (SNT), 4-methoxybenzaldehyde (SMT), 2-hydroxybenzaldehyde (SSTH) or 2-hydroxyacetophenone (SATH) have been studied in refluxing tetrahydrofuran and complexes of types [Cp(2)TiCl(SB)]Cl (SB= SPT, SNT or SMT) and [Cp...

2014
Mi-Kyung Han Moon-Jin Hwang Dae-Hee Won Yang-Soo Kim Ho-Jun Song Yeong-Joon Park

In order to investigate the relationship between phase/microstructure and various properties of Ti-xAg alloys, a series of Ti-xAg alloys with Ag contents ranging from 5 to 20 wt% were prepared. The microstructures were characterized using X-ray diffractometry (XRD), optical microscopy (OM), scanning electron microscopy (SEM) and transmission electron microscopy (TEM). All of the Ti-xAg alloys s...

2005
Carl J. Boehlert Katherine A. Rider Lisa M. Flick

In this work the biocompatibility of two vanadium-free Ti–Al–Nb alloys, Ti–15Al–33Nb and Ti–21Al–29Nb, was evaluated and compared to that for commercially pure titanium (CP Ti) and alumina (Al2O3). Fine particles were milled from sheet-processed material and implanted onto mice calvaria using an established animal model. Various stains, including methylene blue/acid fuchsin, TRAcP, and immunohi...

Journal: :Journal of the American Chemical Society 2007
Denis A Kissounko Justin M Hoerter Ilia A Guzei Qiang Cui Samuel H Gellman Shannon S Stahl

Titanium(IV)-mediated reactions between primary amines and secondary carboxamides exhibit different outcomes, amidine formation versus transamidation, depending on the identity of the TiIV complex used and the reaction conditions employed. The present study probes the origin of this divergent behavior. We find that stoichiometric TiIV, either Cp*TiIV complexes or Ti(NMe2)4, promotes formation o...

نمودار تعداد نتایج جستجو در هر سال