نتایج جستجو برای: contact length
تعداد نتایج: 463828 فیلتر نتایج به سال:
background: silicon hydrogel bandage contact lenses are used to enhance epithelial healing, control surface-generated pain, and prevent epithelial erosions after refractive surgery. considering the importance of faster reepithelialization in preventing complications of photorefractive keratectomy (prk) and the fact that the features and specifications of these commercially-available lenses are ...
This work describes jump-to-contact STM-break junction experiments leading to novel statistical distribution of last-step length associated with conductance of a single atom contact. Last-step length histograms are observed with up to five for Fe and three for Cu peaks at integral multiples close to 0.075 nm, a subatomic distance. A model is proposed in terms of gliding from a fcc hollow-site t...
Acanthamoeba keratitis is increasingly being diagnosed among people who wear thrapeutic and cosmetic contact lenses. The chain of events is thought to begin with contamination of the contact lens storage cases with Acanthamoeba from household or mains water supplies. If bacteria contamination is also present then these amoebas can multiply by ingesting the bacteria as a food source. If the cont...
Contact structures are simplified models of RNA molecules, proteins, and other biopolymer three-dimensional structures. In this paper we study several algebraic representations of biomolecular contact structures and some metrics on sets of contact structures of a given length derived from these representations. We take the opportunity to recall a few problems that remain open in this field of r...
1. to determine whether difference in birth body mass influenced growth performance in pipistrellus kuhlii we studied a total of 12 captive-born neonates. bats were assigned to two body mass groups: light birth body mass (lbw: 0.89 ± 0.05, n=8) and heavy birth body mass (hbw: 1.35 ± 0.08, n=4). heavier body mass at birth was associated with rapid postnatal growth (body mass and forearm length) ...
the resonant frequency and sensitivity of an atomic force microscope (afm) cantilever with assembled cantilever probe (acp) have been analyzed and a closed-form expression for the sensitivity of vibration modes has been obtained. the proposed acp comprises an inclined cantilever and extension, and a tip located at the free end of the extension, which makes the afm capable of topography at sidew...
Graphene-metal contact resistance limits the performance of graphene-based electrical devices. In this work, we have fabricated both graphene field-effect transistors (GFET) and transfer length measurement (TLM) test devices with titanium contacts. The purpose of this work is to compare the contact resistances that can be numerically extracted from the GFETs and measured from the TLM structures...
PURPOSE To assess the repeatability and reliability of IOLMaster (Carl Zeiss Meditec, Inc., Dublin, CA) axial length and keratometry measurements (K readings) with a soft contact lens on normal eyes. The method is designed for eyes with corneal irregularities or after endothelial keratoplasty. METHODS Biometry was performed on 20 healthy right eyes of volunteer subjects with mean age, 27.3 +/...
abstract: in the present paper, we give a necessary and sufficient condition for contact cr-warped product to be contact cr-product in kenmotsu space forms.
This work provides a comprehensive exposition and extension of an atomistically enriched contact mechanics model initially proposed by the present authors. The contact model is based on the coarse-graining of the interaction occurring between the molecules of the contacting bodies. As these bodies may be highly compliant, a geometrically nonlinear kinematical description is chosen. Thus a large...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید