نتایج جستجو برای: aortic prosthesis

تعداد نتایج: 138157  

Journal: :Circulation 1970
S J Lee A J Zaragoza J C Callaghan C M Couves L P Sterns

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

Journal: :JACC. Cardiovascular interventions 2012
Antonio J Muñoz-García José M Hernández-García Manuel F Jiménez-Navarro Juan H Alonso-Briales Antonio J Domínguez-Franco Julia Fernández-Pastor Jose Peña Hernández Alberto Barrera Cordero Javier Alzueta Rodríguez Eduardo de Teresa-Galván

OBJECTIVES The purpose of this study was to evaluate the need for a permanent pacemaker after transcatheter aortic valve implantation with the CoreValve prosthesis (Medtronic, Inc., Minneapolis, Minnesota) using the new Accutrak delivery system (Medtronic, Inc.). BACKGROUND The need for a permanent pacemaker is a recognized complication after transcatheter aortic valve implantation with the C...

2005
SIMON J. K. LEE

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

2014
Anna Marcinkiewicz Stanisław Ostrowski Witold Pawłowski Artur Palczak Anna Adamek-Kośmider Ryszard Jaszewski

We present a case of a 51-year-old male patient hospitalized due to acute coronary syndrome requiring stent implantation to the left main stem. Double antiplatelet therapy was commenced. After 2-3 days, the patient presented with high fever, dyspnea on exertion, pain in the chest, myalgia, and general weakness. Transthoracic (TTE) and transesophageal (TEE) echocardiography revealed abnormal, tu...

Journal: :Journal of the American College of Cardiology 2013
Jan-Malte Sinning Mariuca Vasa-Nicotera Derek Chin Christoph Hammerstingl Alexander Ghanem Johan Bence Jan Kovac Eberhard Grube Georg Nickenig Nikos Werner

Paravalvular aortic regurgitation (PAR) negatively affects the prognosis after transcatheter aortic valve replacement (TAVR) with dramatically increased morbidity and mortality in patients with more than mild PAR. Because transcatheter heart valves are implanted in a sutureless fashion using oversizing to anchor the prosthesis stent frame at the level of the virtual aortic annulus, stent frame ...

Journal: :Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia 2006
Kazuhiro Hashimoto

The concept of patient-prosthesis mismatch (PPM) was defined as existing "when the effective prosthetic valve area, after insertion into the patient, is less than that of a normal valve". However, based on the correlation between the mean transvalvular pressure gradient and the corrected effective orifice area (EOA), PPM is currently defined as an EOA corrected by a body surface area (BSA) of <...

Journal: :Perfusion 2014
Mm Rozeik Dj Wheatley T Gourlay

The aortic valve operates in a complex haemodynamic environment, opening and closing over 100,000 times a day. When complications arise, such as aortic stenosis, prognosis can be very poor, leading to death within the first few years. Surgical valve replacement is currently the standard treatment for aortic stenosis. A thorough understanding of the anatomy and function of the native valve is im...

Journal: :Circulation 1974
R P Seningen B H Bulkley W C Roberts

A cause of early death after aortic valve replacement with a caged-ball prosthesis is obstruction to left ventricular outflow because the prosthesis is too large for the aortic root. Of 68 patients dying within two months of aortic valve replacement, death in ten, each of whom had had intractable low cardiac output after operation, was attributed at necropsy to prosthetic aortic stenosis, despi...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2008
Maximilian A Pichlmaier Omke E Teebken Nawid Khaladj Jürgen Weidemann Michael Galanski Axel Haverich

OBJECTIVE The frozen elephant trunk technique allows the repair of concomitant aortic arch and proximal descending aortic pathology in a single stage by using a hybrid prosthesis consisting of a vascular graft with a distal stented end. There are patients, however, who will require a second distal operation despite this new technique due to progression of their aortic disease. It has been uncle...

Journal: :European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery 2016
Michael Scharfschwerdt Moritz Leonhard Judith Lehmann Doreen Richardt Helmut Goldmann Hans-Hinrich Sievers

OBJECTIVES Prosthetic replacement of the thoracic aorta with common Dacron prostheses impairs the aortic 'windkessel' and, in valve-sparing procedures, also aortic valve function. Elastic graft material may overcome these deficiencies. METHODS Fresh porcine aortas including the root were set up in a mock circulation before and after replacement of the ascending part with a novel vascular pros...

نمودار تعداد نتایج جستجو در هر سال