نتایج جستجو برای: دزیمتر thermoluminescence dosimeter

تعداد نتایج: 3142  

2012
Imre Vass Narendranath Mohanty Sándor Demeter

The effect of photoinhib i t ion on the pr imary ( O a ) and secondary ( O b ) quinone acceptors of photosystem I I was investigated in isolated spinach thylakoids by the methods of thermoluminescence and delayed luminescence. The amplitudes of the Q (at about 2 °C) and B (at about 30 °C) thermoluminescence bands which are associated w i th the recombination of the S ;OA and S2QB charge pairs, ...

Journal: :Thorax 1988
M M Nieminen A Lahdensuo L Kellomaeki J Karvonen A Muittari

A new inhalation synchronised dosimeter triggered by low inspiratory flow rates has been assessed. The methacholine challenge test using dosimeter nebulisation with controlled tidal breathing was compared with continuous nebulisation using De Vilbiss No 40 nebulisers with deep inhalations in 11 asthmatic subjects. Within subject PD20 FEV1 values were lower with the dosimeter method than with th...

Journal: :International journal of radiation oncology, biology, physics 2012
J Lah D Kim S Park

PURPOSE To evaluate the suitability of the GD-301 glass dosimeter for use in in vivo dose verification in proton therapy. METHODS The glass dosimeter was analyzed for its dosimetric characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stair-like holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurement...

ژورنال: :سنجش و ایمنی پرتو 0
احسان صادقی ehsan sadeghi university of kashanکاشان مصطفی زاهدی فر mostafa zahedifar university of kashanکاشان محسن محرابی mohsen mehrabi university of kashanدانشگاه کاشان

در این تحقیق، امکان استفاده از دزیمتر al2o3:c-α (tld-500) برای تخمین دز گاما در میدان های مرکب نوترون و گاما با استفاده از روش نسبت دو قله بررسی شد. قلۀ اصلی این دزیمتر از دو قله همپوش تشکیل شده است. نسبت شدت گرماتابی قلۀ 2 به قلۀ 1 این دزیمتر در میدان خالص گاما (137cs) 49/1 و برای میدان نوترون am-be این نسبت 12/1 به دست آمد. قرص های tld-500 مشخص به طور جداگانه، از 7 درصد تا 48 درصد دز کل در 6 ...

2004
R. H. Bartram A. Lempicki L. A. Kappers D. S. Hamilton

A sample of Eu-activated lutetium sesquioxide transparent ceramic has been investigated by combined scintillation and thermoluminescence excited by prolonged gamma-ray irradiation. The thermoluminescence glow curve partially confirms and extends a previous model for afterglow following pulsed X-ray excitation. The initial concentration of hole traps, tentatively attributed to anion Frenkel defe...

2008
Bojana Šećerov Goran Bačić

Radiation processing in many areas, particularly in radiation sterilization, demands control of the absorbed dose. Many dosimeters have been proposed for the high-level dose range (region of 10 to 50 kGy). However, in addition to the required reproducibility, reliability or uncertainty (< 5%), it is desirable for radiation processing that the selected dosimetric system is easy to operate. One o...

Journal: :Medical physics 2015
Kelsey Chisholm Devin Miles Leith Rankine Mark Oldham

PURPOSE In optical-CT, the use of a refractively matched polyurethane solid-tank in place of a fluid bath has the potential to greatly increase practical convenience, reduce cost, and possibly improve the efficacy of flood corrections. This work investigates the feasibility of solid-tank optical-CT imaging for 3D dosimetry through computer simulation. METHODS A matlab ray-tracing simulation p...

Journal: :Chest 2005
Donald W Cockcroft Beth E Davis David C Todd Audrey J Smycniuk

BACKGROUND Guidelines for the 2-min tidal-breathing and the five-breath dosimeter methods for methacholine challenge have recently been published by the American Thoracic Society (ATS). Although subjects are exposed to twice as much aerosol at any given concentration during the tidal-breathing method compared to the dosimeter method, they were thought to give equivalent results. OBJECTIVE To ...

Journal: :The European respiratory journal 1991
A J Knox A Wisniewski S Cooper A E Tattersfield

Bronchial reactivity is being measured with increasing frequency in epidemiological studies, but there debate continues about the relative merits of the different methods used to measure reactivity, particularly for subjects with no previous experience of reactivity testing as is the case in epidemiological studies. Repeatability is likely to improve with practice, and laboratory based studies ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید