نتایج جستجو برای: الیاف uhmwpe

تعداد نتایج: 5521  

2014
Christopher Reyes Shannon Rowell Charles Engh Robert Hopper Orhun Muratoglu

Introduction: Ultra-high molecular weight polyethylene (UHMWPE) is the most widely used bearing surface option in total hip arthroplasty. Radiation cross-linking has improved the wear resistance of conventional UHMWPE. Radiation cross-linking also generates residual free radicals, adversely affecting long-term oxidative stability. Post irradiation melting is effectively used to eliminate residu...

2008
L. V. Wilches J. A. Uribe A. Toro

Two tribological pairs used for artificial joints were studied. Wear tests were performed in a pin-on-disc type machine modified to allow lubrication ith bovine serum. The pins were made of either AISI F138 stainless steel or ASTM F136 titanium alloy, while the discs were manufactured with ltra-high molecular weight polyethylene (UHMWPE). The tested pairs were ASTM F138 stainless steel–UHMWPE a...

2010
Sheryl R. Kane Paul D. Ashby Lisa A. Pruitt

The predominant cause of late-state failure of total hip replacements is wear-mediated osteolysis caused by wear particles that originate from the ultrahigh molecular weight polyethylene (UHMWPE) acetabular cup surface. One strategy for reducing wear particle formation from UHMWPE is to modify the surface with a hydrophilic coating to increase lubrication from synovial fluid. This study focuses...

2016
A C Paulus S Haßelt V Jansson A Giurea H Neuhaus T M Grupp S Utzschneider

Introduction. Increasing interest developed in the use of carbon-fiber-reinforced-poly-ether-ether-ketones (CFR-PEEK) as an alternative bearing material in knee arthroplasty. The effects of CFR-PEEK wear in in vitro and animal studies are controversially discussed, as there are no data available concerning human tissue. The aim of this study was to analyze human tissue containing CFR-PEEK as we...

2017
Tatsuro Sasaji Hideki Imaizumi Taishi Murakami

Low transverse sacral fractures are rare, with only two published reports regarding their surgery. The complication associated with surgery for sacral fractures is the prominence of implants. In addition, screw fixation below S3 is impractical. We performed posterior sacral fixation using S2 alar iliac (S2AI) screws and sacral sublaminar wires for low transverse sacral fractures. Case 1 was 65-...

Journal: :The Journal of bone and joint surgery. British volume 1998
H Minakawa M H Stone B M Wroblewski J G Lancaster E Ingham J Fisher

We examined stainless-steel, cobalt-chrome, titanium and alumina and zirconia ceramic femoral heads retrieved at revision surgery. All the heads had articulated against ultra-high-molecular-weight-polyethylene (UHMWPE) acetabular cups. We studied the simulation of third-body damage and the wear of UHMWPE against the various materials used for the heads. The surfaces of the retrieved heads were ...

Journal: :Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine 2013
Abdellatif Abdelgaied Claire L Brockett Feng Liu Louise M Jennings John Fisher Zhongmin Jin

Polyethylene wear is a great concern in total joint replacement. It is now considered a major limiting factor to the long life of such prostheses. Cross-linking has been introduced to reduce the wear of ultra-high-molecular-weight polyethylene (UHMWPE). Computational models have been used extensively for wear prediction and optimization of artificial knee designs. However, in order to be indepe...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2009
Ryan M Baxter Marla J Steinbeck Joanne L Tipper Javad Parvizi Michele Marcolongo Steve M Kurtz

There is considerable interest in characterization of wear debris from polyethylene (UHMWPE) bearing components used in total joint replacement. To isolate UHMWPE wear debris, tissue samples must be excised from regions adjacent to revised UHMWPE implant components, followed by exposure to one of many available tissue digestion methods. Numerous studies demonstrate successful digestion, but the...

Journal: :Biomaterials 2003
S J Charlebois A U Daniels G Lewis

In this work, isothermal microcalorimetry (IMC) was utilized to measure the exothermic heat flow from specimens of ultra-high-molecular-weight polyethylene (UHMWPE), that had been sterilized by various standard methods, under simulated shelf storage (air at 25 degrees C, 30% r.h.) and simulated implantation (phosphate buffered saline, PBS, at 37 degrees C) conditions. Gamma-radiation sterilized...

Journal: :Journal of biomedical materials research. Part B, Applied biomaterials 2010
Angela L Bruck K S Kanaga Karuppiah Sriram Sundararajan Jun Wang Zhiqun Lin

In this study, the friction and wear behavior of ultrahigh molecular weight polyethylene (UHMWPE) were evaluated as a function of polymer crystallinity in the presence of the phospholipid dipalmitoyl phosphatidylcholine (DPPC) dissolved in ethanol. Samples of UHMWPE were separately heat treated to get high and low crystallinity samples. Degree of crystallinity was evaluated using differential s...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید