Journal: :Journal of synchrotron radiation 1998
D Shu T M Kuzay Y Fang J Barraza T Cundiff

A novel X-ray beam-position detection device that we call a position-sensitive photoconductive detector (PSPCD) is designed to have synthetic diamond as its substrate material. We proved that it is feasible to use synthetic diamond to make a hard X-ray position-sensitive detector based on the photoconductivity principle and that it acts as a solid-state ion chamber. Experiments on different PSP...

2008
Tadayuki Takahashi Richard Kelley Kazuhisa Mitsuda Hideyo Kunieda Robert Petre Nicholas White Tadayasu Dotani Ryuichi Fujimoto Yasushi Fukazawa Kiyoshi Hayashida Manabu Ishida Yoshitaka Ishisaki Motohide Kokubun Kazuo Makishima Katsuji Koyama Greg M. Madejski Koji Mori Richard Mushotzky Kazuhiro Nakazawa Yasushi Ogasaka Takaya Ohashi Masanobu Ozaki Hiroyasu Tajima Makoto Tashiro Yukikatsu Terada Hiroshi Tsunemi Takeshi Go Tsuru Yoshihiro Ueda Noriko Yamasaki Shin Watanabe

The NeXT (New exploration X-ray Telescope), the new Japanese X-ray Astronomy Satellite following Suzaku, is an international X-ray mission which is currently planed for launch in 2013. NeXT is a combination of wide band X-ray spectroscopy (3–80 keV) provided by multi-layer coating, focusing hard X-ray mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (...

Introduction: Regular implementation of quality control (QC) program in diagnostic X-ray facilities may affect both image quality and patient radiation dose due to the changes in exposure parameters. Therefore, this study aimed to investigate the status of randomly selected conventional radiographic X-ray devices installed in radiology centers of Great Khorasan Province, Iran, to produce the da...

2015
D. Bowes H. Yin D. Chen

X-ray emission has been achieved using an electron beam generated by a pseudospark low-pressure discharge and utilised as a diagnostic for beam detection. A 300 A, 34 kV PS-sourced electron beam pulse of 3 mm diameter impacting on a 0.1 mm-thick molybdenum target generated X-rays which were detected via the use of a small, portable X-ray detector. Clear X-ray images of a micro-sized object were...

Journal: :Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2006

2003
Koichi Hiratsuka Toshihiko Sasaki Yukio Hirose

A single exposure X-ray incidence method for determining stress using the whole part of the Debye-Scherrer ring was studied. An image plate (IP) was used in this study as an area detector. A stress measuring system using an X-ray two-dimensional detector was developed. This was designed in order to be used in the authors’ X-ray laboratory. The background and the purpose of this study is to poin...

2014
Seungman Yun Jong Chul Han Dong Woon Kim Hanbean Youn Ho Kyung Kim Jesse Tanguay Ian A. Cunningham

We revisit the doubly-layered sandwich detector con guration for single-shot dual-energy x-ray imaging. In order to understand its proper operation, we investigated the contrast-to-noise performance in terms of the x-ray beam setup using the Monte Carlo methods. Using a pair of active photodiode arrays coupled to phosphor screens, we have built a sandwich detector. For better spectral separatio...

2016
Hugh T. Philipp Mark W. Tate Prafull Purohit Katherine S. Shanks Joel T. Weiss Sol M. Gruner

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8-12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration ca...

2007
S. L. Barna J. A. Shepherd R. L. Wixted M. W. Tate B. Rodricks S. M. Gruner

A large-area pixel x-ray detector is being developed to collect eight successive frames of wide dynamic range two-dimensional images at 200kHz rates. Such a detector, in conjunction with a synchrotron radiation x-ray source, will enable time-resolved x-ray studies of proteins and other materials on time scales which have previously been inaccessible. The detector will consist of an array of ful...

Journal: :iranian journal of radiation research 0
h. arabi radiation medicine department, shahid beheshti university, tehran, iran a.r. kamali asl radiation medicine department, shahid beheshti university, tehran, iran s.m. aghamiri radiation medicine department, shahid beheshti university, tehran, iran

background: a variable resolution x-ray (vrx) ct scanner provides a great increase in the spatial resolution. in vrx ct scanners, the spatial resolution of the system and its field of view (fov) can be changed according to the object size. one of the main factors that limit the spatial resolution of vrx ct scanner is the effect of the x-ray focal spot. materials and methods: a theoretical study...