نتایج جستجو برای: wet cooling tower

تعداد نتایج: 98302  

2007
Donald Kasten Michael R. Muller

Traditionally, energy recommendations from energy audits have been concerned with the energy use of cooling towers for point of use energy, such as variable speed fans, and pumping savings. The actual energy use of a cooling tower is small, and is only a portion of the energy involved in the entire cooling system. The majority of the energy used is to perform the work necessary to compress the ...

2011
A. M. El Ansary A. A. El Damatty A. O. Nassef

The aim of the current study is to develop a numerical tool that is capable of achieving an optimum shape and design of hyperbolic cooling towers based on coupling a non-linear finite element model developed in-house and a genetic algorithm optimization technique. The objective function is set to be the minimum weight of the tower. The geometric modeling of the tower is represented by means of ...

2015
Ahmad Fazlizan Wen Tong Chong Sook Yee Yip Wooi Ping Hew Hossam A. Gabbar

A vertical axis wind turbine (VAWT) was positioned at the discharge outlet of a cooling tower electricity generator. To avoid a negative impact on the performance of the cooling tower and to optimize the turbine performance, the determination of the VAWT position in the discharge wind stream was conducted by experiment. The preferable VAWT position is where the higher wind velocity matches the ...

Babak Ghaem Panah Hassan Shokouhmand Mohammad Ali Nazari Mohammad Reza Aligoodarzi

In this paper the effect of site conditions, which are Altitude, Temperature and Relative Humidity and also Heat Dissipation Capacity are investigated on the optimized design of natural draft dry cooling towers with specific kind of heat exchangers, known as Forgo T60 type. A genetic algorithm program has been developed for optimized design of these cooling towers. Objective function includes b...

2013
W. T. Chong A. Fazlizan S. Y. Yip S. C. Poh W. P. Hew E. P. Tan T. S. Lim

The exhaust air energy recovery wind turbine generator is an on-site clean energy generator that utilizes the advantages of discharged air which is strong, consistent and predictable. Two vertical axis wind turbines (VAWTs) in cross-wind orientation which are integrated with an enclosure are installed above a cooling tower to harness the discharged wind for electricity generation. It is mounted...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه بوعلی سینا - دانشکده فنی 1387

چکیده ندارد.

Journal: :Energies 2021

Gas turbine inlet air-cooling (TIAC) is an established technology for augmenting gas output and efficiency, especially in hot regions. TIAC using evaporative cooling suitable hot, dry regions; however, the limited by ambient wet-bulb temperature. This study investigates two-stage under harsh weather of Riyadh city. The system consists indirect direct stages. In stage, air precooled water cooled...

Journal: :Ozone: Science & Engineering 1981

Journal: :معماری و شهرسازی 0
محمدجواد مهدوی نژاد استادیار گروه معماری دانشکده هنر و معماری، دانشگاه تربیت مدرس کاوان جوانرودی دانشجوی کارشناسی‎ارشد معماری-گرایش فنی، دانشکده هنر و معماری، دانشگاه تربیت مدرس

this article is a comparative evaluation of airflow in two kinds of yazdi and kermani wind-towers. in the late decades of twenty century regarding to high population growth rate and energy crisis, vernacular architecture and its passive methods for gaining thermal comfort, has been strongly focused. moreover, a huge scientific movement setup for researches deep in exploring passive cooling and ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید