نتایج جستجو برای: viscous damper system damper configuration tabas earthquake ansys dynamic response
تعداد نتایج: 3428758 فیلتر نتایج به سال:
In the area of semi-active control of civil structures, Magneto-Rheological (MR) damper has been an efficient mechanism for reducing the seismic response of structures. In this paper, an effective method based on defining an optimization problem for designing MR dampers has been proposed. In the proposed method, the parameters of semi-active control system are determined so that the maximum res...
A new semiactive control strategy for seismic response reduction using a neurocontroller and a magnetorheological (MR) fluid damper is proposed. The proposed control system adopts a clipped algorithm which induces the MR damper to generate approximately the desired control force. The improved neuro-controller, which was developed by employing the training algorithm based on a cost function and ...
The damped outrigger system is in widespread seismic area as a damping modification system. However, the relationships between exact performance and its response reduction effect has not been deeply investigated yet. This paper non-linear dynamic characteristic of single-damped systems with oil dampers or elasto-plastic considering design earthquake levels. optimal damper equations to maximize ...
This paper studies the solution behavior of a system of two coupled elastic beams connected vertically by springs. With the viscous damping collocated with the ends of the springs, the system energy decays exponentially. Our goal is to find the optimal spring-damper location which yields the best energy decay rate of the beam-spring system.
in this study, mass, stiffness and damping matrices of the nosrat jacket; located in persian gulf; equipped with semi active tuned mass damper (satmd) system have been derived after modeling the structure in sacs software. owing to huge number of the degrees of freedom in the model, computation of on-line control of satmd was time consuming. for this purpose, the size of the model was reduced i...
Experimental Study on Seismic Response Mitigation of Complex Structure using Passive Friction Damper
The application of control devices in coupled building system has been recently recognized as an effective alternative for seismic protection. In consideration of passive control approach, most of previous studies focused on application of fluid dampers, and the buildings in the coupled systems were in similar structural configuration. By recognizing the potential merits, such as simple in desi...
Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, ...
Magnetorheological dampers have raised as promising devices for structural seismic protection since they have many attractive features such as small power requirements, reliability, and relatively low cost. These devices have strongly nonlinear behaviour which is very difficult to characterize. For this reason, the modelling of MR dampers has been an active field during the last years and has p...
This paper investigated the dynamic response characteristic with focus on damped slit configuration of braced tube systems oil dampers. According to results, 1) system has over 10% 1st 3rd damping ratio, 2) while displacement and acceleration responses are simultaneously reduced up maximized mode reduction effect may be getting worse after peak, 3) uniform damper distribution contributes better...
The present article seek to investigate the function of elliptical steel damper function in steel frames seismic resisting. The elliptical damper is a kind of earthquake energy dissipater in structure which acts based on the steel yielding feature. Thus, this damper in frame lateral displacement mechanism is expected to have a satisfying hysteretic behavior in terms of energy absorption is on a...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید