نتایج جستجو برای: transit dosimetry epid

تعداد نتایج: 29182  

Ahmad Mostaar, Golbarg esmailie Hassan Nedaei Mohammad Amin Mosleh Shirazi Seied Rabi Mahdavi, Vahideh Nazari

Introduction: Tumor control and treatment quality depend on accuracy of delivered dose. Various methods have been studied for treatment dosimetry verification. Among these methods, the use of electronic portal imaging device (EPID) is highly considered. Many efforts are underway to improve the results of this context.   Materials and Methods: In this study, ...

Journal: :iranian journal of radiation research 0
a. jomehzadeh medical physics department, isfahan university of medical sciences, isfahan, iran p. shokrani medical physics department, isfahan university of medical sciences, isfahan, iran m. mohammadi medical physics department, hamadan university of medical sciences, hamadan, iran a. amouheidari radiation oncology department, isfahan milad hospital, isfahan, iran

background: electronic portal imaging devices (epids) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. a successful utilization of epids for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. in this study, two in-house phantoms were developed and analyzed for implementation in a qua...

A. Amouheidari, A. Jomehzadeh, M. Mohammadi, P. Shokrani,

Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...

2013
Bo Liu Justus Adamson Anna Rodrigues W Ansbacher I M Gagne

Purpose: To develop and validate a pre-treatment EPI dosimetry method on Varian TrueBeam linacs using continuous imaging, with reconstruction in a 3D cylindrical phantom geometry. Methods: Delivery of VMAT plans with continuous imaging is currently possible only in Research Mode on TrueBeam linacs, with images acquired in a proprietary format. An earlier technique was adapted to take advantage ...

2015
Charbel Merheb Clément Chevillard Wassim Ksouri Maher Fawzi Marc Bollet Alain Toledano

Several algorithms exist to perform quality assurance for volumetric-modulated arc therapy (VMAT) treatments based on electronic portal imaging devices (EPID). These algorithms are used to compare doses (convert into water, GLAaS) and fluences (in amorphous silicon (aSi), Varian portal dosimetry). The aim of this study is to compare the two methods using clinical data. In this study, Varian por...

2011
Indra J. Das Minsong Cao Chee‐Wai Cheng Vladimir Misic Klaus Scheuring Edmund Schüle Peter A.S. Johnstone

Electronic portal imaging device (EPID) plays an important role in radiation therapy portal imaging, geometric and dosimetric verification. Consistent image quality and stable radiation response is necessary for proper utilization that requires routine quality assurance (QA). A commercial 'EPID QC' phantom weighing 3.8 kg with a dimension of 25 × 25 × 4.8 cm³ is used for EPID QA. This device ha...