نتایج جستجو برای: spherical aberration
تعداد نتایج: 53854 فیلتر نتایج به سال:
PURPOSE To compare the effect of spherical aberration on optical quality in eyes with two different aspherical intraocular lenses. METHODS 120 eyes of 60 patients underwent phacoemulsification. In patients' eyes, an aberration-free IOL (Aspira-aA; Human Optics) or an aberration-correcting aspherical IOL (Tecnis ZCB00; Abott Medical Optics) was randomly implanted. After surgery, contrast sensi...
Traditionally, aberration correction in extreme ultraviolet (EUV) projection optics requires the use of multiple lossy mirrors, which results in prohibitively high source power requirements. We analyze a single spherical mirror projection optical system where aberration correction is built into the mask itself, through Inverse Lithography Technology (ILT). By having fewer mirrors, this would re...
We study the Gouy phase of a scalar wavefield that is focused by a lens suffering from primary spherical aberration. It is found that the Gouy phase has different behaviors at the two sides of the intensity maximum. This results in a systematic increase of the successive wavefront spacings around the diffraction focus. Since all lenses have some amount of spherical aberration, this observation ...
The ideal location for an aberration corrector in an electron-optical column is at the place where the aberration is introduced. In practice, this of course typically cannot be achieved. The resultant separation between where an aberration is introduced and where it is removed produces combination aberrations for all aberrations of higher than first order. In the case of third-order aberration ...
We read with interest the article by Esteve-Taboada et al.1 The authors measured the modulation transfer function (MTF) of three intraocular lenses (IOLs) using a corneal eye model with zero spherical aberration using monochromatic light. This means that corneal higher order aberrations and chromatic aberration were not taken into account for the evaluation, even though it has been shown that s...
PURPOSE To define the corneal optics of conductive keratoplasty (CK) and assess the clinical implications for hyperopia and presbyopia management. METHODS Four analyses were done. (1) Multifocal effects: In a prospective study of CK, uncorrected visual acuity (UCVA) for a given refractive error in 72 postoperative eyes was compared to control eyes. (2) Surgically induced astigmatism (SIA): 20...
A wavefront sensorless adaptive optics technique was combined with a custom-made multiphoton microscope to correct for specimen-induced aberrations. A liquid-crystal-on-silicon (LCoS) modulator was used to systematically generate Zernike modes during image recording. The performance of the instrument was evaluated in samples providing different nonlinear signals and the benefit of correcting hi...
Spherical aberration arising from deviations of the thickness of an optical disc substrate from a nominal value can be compensated to a great extent by illuminating the scanning objective lens with a slightly convergent or divergent beam. The optimum conjugate change and the amount and type of residual aberration are calculated analytically for an objective lens that satisfies Abbe's sine condi...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید