نتایج جستجو برای: solid phantom

تعداد نتایج: 206123  

2010
Åsa Palm Elisabeth Nilsson Lars Herrnsdorf

According to published data, the absorbed dose used for a CBCT image acquisition with Varian OBI v1.3 can be as high as 100 mGy. In 2008 Varian released a new OBI version (v1.4), which promised to reduce the imaging dose. In this study, absorbed doses used for CBCT image acquisitions with the default irradiation techniques of Varian OBI v1.3 and v1.4 are measured. TLDs are used to derive dose d...

2001
Cheng Yu Zbigniew Petrovich Michael L. J. Apuzzo Gary Luxton

A special acrylic phantom designed for both magnetic resonance imaging (MRI) and computed tomography (CT) was used to assess the geometric accuracy of MRI-based stereotactic localization with the Leksell stereotactic head frame and localizer system. The acrylic phantom was constructed in the shape of a cube, 164 mm in each dimension, with three perpendicular arrays of solid acrylic rods, 5 mm i...

2016
Petra M Härtl Marius Treutwein Matthias G Hautmann Manuel März Fabian Pohl Oliver Kölbl Barbara Dobler

INTRODUCTION A sweeping beam technique for total body irradiation in standard treatment rooms and for standard linear accelerators (linacs) is introduced, which does not require any accessory attached to the linac. Lung shielding is facilitated to reduce the risk of pulmonary toxicity. Additionally, the applicability of a commercial radiotherapy planning system (RTPS) is examined. MATERIAL AN...

Journal: :Medical physics 2014
D Lewis P Summers D Followill N Sahoo A Mahajan F Stingo S Kry

PURPOSE To design an anthropomorphic pediatric spine phantom for use in the evaluation of proton therapy facilities for clinical trial participation by the Imaging and Radiation Oncology Core (IROC) Houston QA Center (formerly RPC). METHODS This phantom was designed to perform an end-to-end audit of the proton spine treatment process, including simulation, dose calculation by the treatment pl...

2008
Ramani Ramaseshan Kirpal Kohli Fred Cao Robert Heaton

High-precision radiotherapy planning and quality assurance require accurate dosimetric and geometric phantom measurements. Phantom design requires materials with mechanical strength and resilience, and dosimetric properties close to those of water over diagnostic and therapeutic ranges. Plastic Water Diagnostic Therapy (PWDT: CIRS, Norfolk, VA) is a phantom material designed for water equivalen...

 ABSTRACTBackground: Monte Carlo simulation has been used by many researchers to calculate organ and effective dose of patients arising from conventional X-ray examinations. In this study the radiation transport code, MCNP-4C, has been used to perform Monte Carlo simulations to estimate radiation dose delivered to different organs in conventional X-ray examinations.Material and Methods: In this...

Journal: :iranian journal of radiation research 0
c.a. davis department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman r. ravichandran department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman j.p. binukumar department of radiotherapy, national oncology center, royal hospital, muscat, sultanate of oman k. el ghamrawy department of radiation oncology, university of cairo, cairo, egypt

background: for radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. the details of dosimetry, clinical dose measurements are presented. materials and methods: the treatment planned with 6 overlapping 9 mev electron fields in ...

Journal: :Nuclear Instruments & Methods in Physics Research Section B-beam Interactions With Materials and Atoms 2023

The Geant4 toolkit was used to perform benchmark Monte Carlo simulations of proton micro-tomography imaging. A phantom an inertial confinement fusion (ICF) target designed, based on experimental data. Simulations STIM (Scanning Transmission Ion Microscopy) and PIXE (Particle Induced X-ray Emission) tomography were performed. Quantitative images obtained from the TomoRebuild JPIXET software pack...

Journal: :iranian journal of medical physics 0
asghar mesbahi department ofmedical physics, medical school, tabriz university of medical sciences,,tabriz, iran. 2- department ofradiation oncology, imam hospital, tabriz, iran. ismail zergoug 3-department of radiotherapy, emir abdelkaderanti-cancer center, oran, algeria

introduction radiotherapy with small fields is used widely in newly developed techniques. additionally, dose calculation accuracy of treatment planning systems in small fields plays a crucial role in treatment outcome. in the present study, dose calculation accuracy of two commercial treatment planning systems was evaluated against monte carlo method. materials and methods siemens once or linea...

نمودار تعداد نتایج جستجو در هر سال