2014
Wei Loong Jong Jeannie Hsiu Ding Wong Ngie Min Ung Kwan Hoong Ng Gwo Fuang Ho Dean L. Cutajar Anatoly B. Rosenfeld

In vivo dosimetry is important during radiotherapy to ensure the accuracy of the dose delivered to the treatment volume. A dosimeter should be characterized based on its application before it is used for in vivo dosimetry. In this study, we characterize a new MOSFET-based detector, the MOSkin detector, on surface for in vivo skin dosimetry. The advantages of the MOSkin detector are its water eq...

Journal: :Bioelectromagnetics 2005
Stefan Engström Marko S Markov Michael J McLean Robert A Jones Robert R Holcomb

We describe devices designed for magnetic field exposures in which field amplitude and gradients are controlled simultaneously. Dosimetry based on field continuation of high resolution magnetic field scans and numerical models is compared with validation measurements. The dosimetry variables we consider are based on the assumption that the biological or chemical system under study has field tra...

2013
Guerda Massillon-JL Diego Cueva-Prócel Porfirio Díaz-Aguirre Miguel Rodríguez-Ponce Flor Herrera-Martínez

This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (...

2012
M.L. Taylor T. Kairn T. Kron L. Dunn P.N. Johnston R.D. Franich

The objective of this work is to quantify the systematic errors introduced by the common assumption of invariant secondary electron spectra with changing field sizes, as relevant to stereotactic radiotherapy and other treatment modes incorporating small beam segments delivered with a linac-based stereotactic unit. The EGSnrc/BEAMnrc Monte Carlo radiation transport code was used to construct a d...

Alireza Karimian, Clara Ferreira Iraj Jabari Neda Gholizadeh Sendani Parham Alaei S. Rabie Mahdavi

Introduction: Accurate film dosimetry requires careful consideration of sources of uncertainty. Some of the sources of uncertainty are dependent on the size and location of region of interest (ROI), especially in small fields. Avoiding the penumbra is often a reason for using a small ROI. In contrast, choosing very small ROIs may increase uncertainty due to the reduction of th...

2017
C Baldock

John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and incl...

Journal: :Sensors and Actuators A-physical 2021

The Investigations of this article focus on the response Al2O3:C and Al2O3:C,Mg radioluminescence films for medical dosimetry in various MV photon beams. A system was configured using a scientific camera, attached to head linear accelerator (LINAC), facing beam’s isocenter, where were placed. By appropriate filter lens it is possible measure real time two-dimensional dose-rate distributions. ke...