نتایج جستجو برای: siemens primus linac

تعداد نتایج: 9554  

Journal: :journal of biomedical physics and engineering 0
m ghorbani medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran z s tabatabaei medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran a vejdani noghreiyan medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran h vosoughi medical physics department, faculty of medicine, mashhad university of medical sciences, mashhad, iran c knaup comprehensive cancer centers of nevada, las vegas, nevada, usa

objective: the aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy. methods : a siemens primus linear accelerator and a phantom were simulated using mcnpx monte carlo code. in a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. the tissues included muscle (s...

2015
M. Ghorbani Z. S. Tabatabaei A. Vejdani Noghreiyan H. Vosoughi C. Knaup

OBJECTIVE The aim of this study is to evaluate the effect of tissue composition on dose distribution in electron beam radiotherapy. METHODS A Siemens Primus linear accelerator and a phantom were simulated using MCNPX Monte Carlo code. In a homogeneous cylindrical phantom, six types of soft tissue and three types of tissue-equivalent materials were investigated. The tissues included muscle (sk...

Introduction: The evaluation of X-ray and light field coincidence in linear accelerators as a quality control test is often performed subjectively, involving the manual marking of films and their visual inspection following the irradiation. Therefore, the present study aimed to develop an objective method for the performance of this test leading to the increased levels...

2015
Mohamad M. Alabdoaburas Jean‐Pierre Mege Jean Chavaudra Jérémi Vũ Bezin Attila Veres Florent de Vathaire Dimitri Lefkopoulos Ibrahima Diallo

The purpose of this work was to experimentally investigate the out-of-field dose in a water phantom, with several high energy electron beams used in external beam radiotherapy (RT). The study was carried out for 6, 9, 12, and 18 MeV electron beams, on three different linear accelerators, each equipped with a specific applicator. Measurements were performed in a water phantom, at different depth...

2013
N. Chegeni M. J. Tahmasebi Birgani

Equivalent fields are frequently used for central axis depth-dose calculations of rectangular and irregular shaped photon beam. Since most of the proposed models to calculate the equivalent square field, are dosimetry-based, a simple physical-based method to calculate the equivalent square field size was used as the basis of this study. The table of the sides of the equivalent square for rectan...

2003
S. H. Cho G. S. Ibbott

The dosimetric characteristics for modern computer-controlled linear accelerators with the same make, model, and nominal energy are known to be very similar, as long as the machines are unaltered from the manufacturer's original specifications. In this preliminary study, a quantitative investigation of the similarity in the basic photon dosimetry data from the Siemens Primus linear accelerators...

2013
Mohamad Javad Tahmasebi Birgani Nahid Chegeni Shole Arvandi Sasan Razmjoo Ghalaee Mansoor Zabihzadeh Davood Khezerloo

Nowadays, in most radiotherapy departments, the commercial treatment planning systems (TPS) used to calculate dose distributions needs to be verified; therefore, quick, easy-to-use, and low-cost dose distribution algorithms are desirable to test and verify the performance of the TPS. In this paper, we put forth an analytical method to calculate the phantom scatter contribution and depth dose on...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید