نتایج جستجو برای: radiotherapy setup errors

تعداد نتایج: 233995  

2007
James G. Mechalakos Margie A. Hunt Nancy Y. Lee Linda X. Hong C. Clifton Ling Howard I. Amols

The purpose of the present study was to use a kilovoltage imaging device to measure interfractional and intrafractional setup deviations in patients with head-and-neck or brain cancers receiving intensity-modulated radiotherapy (IMRT) treatment. Before and after IMRT treatment, approximately 3 times weekly, 7 patients were imaged using the Varian On-Board Imager (OBI: Varian Medical Systems, Pa...

H.R. Khosravi, K. Asnaashari, S. Gholami,

Background: The purpose of this work is to discover and analyze errors and incidents in some radiotherapy centers, and to introduce methods that could reduce their occurrences, especially those which had happened due to the use of improper and inadequate equipment. This work is a first step toward clarifying the role of education in a risk-conscious culture, and changing the attitude of radioth...

2013
Kanan Jassal

To compare the set-up uncertainties in breast radiation therapy using two different immobilization methods: vacuum cushion (VC) and standard breast board (BB). The data set comprises of 26 breast cases were divided into two groups based on the type of immobilization used for their radiotherapy treatment, either intensity-modulated radiotherapy (IMRT) or volumetric arc modulated radiotherapy (VM...

2016
Ya-Ting Jan Chih-Long Chang Hung-Chi Tai Yu-Chuen Huang Chia-Ling Liao Yu-Jen Chen

PURPOSE Radiotherapy with concurrent chemotherapy has been recommended as standard treatment for locally advanced cervical cancer. To validate the main tumor location before each high-precision helical tomotherapy (HT) fraction, the development of a more reliable marker or indicator is of clinical importance to avoid inadequate coverage of the main tumor. MATERIAL AND METHODS A 61-year-old wo...

2015
Minglun Li Hendrik Ballhausen Nina-Sophie Hegemann Ute Ganswindt Farkhad Manapov Stefan Tritschler Alexander Roosen Christian Gratzke Michael Reiner Claus Belka

BACKGROUND The accuracy of the Elekta Clarity™ three-dimensional ultrasound system (3DUS) was assessed for prostate positioning and compared to seed- and bone-based positioning in kilo-voltage cone-beam computed tomography (CBCT) during a definitive radiotherapy. METHODS The prostate positioning of 6 patients, with fiducial markers implanted into the prostate, was controlled by 3DUS and CBCT....

2018
Noora Al-Hammadi Palmira Caparrotti Carole Naim Jillian Hayes Katherine Rebecca Benson Ana Vasic Hissa Al-Abdulla Rabih Hammoud Saju Divakar Primoz Petric

Background During radiotherapy of left-sided breast cancer, parts of the heart are irradiated, which may lead to late toxicity. We report on the experience of single institution with cardiac-sparing radiotherapy using voluntary deep inspiration breath hold (V-DIBH) and compare its dosimetric outcome with free breathing (FB) technique. Patients and methods Left-sided breast cancer patients, tr...

2015
Marko Laaksomaa Mika Kapanen Mikko Haltamo Tanja Skyttä Seppo Peltola Simo Hyödynmaa Pirkko-Liisa Kellokumpu-Lehtinen

BACKGROUND Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. METHODS 1067 sets of images with an orthogonal setup and tangenti...

Journal: :Radiation Oncology (London, England) 2009
Reinhold Graf Peter Wust Volker Budach Dirk Boehmer

BACKGROUND To evaluate the benefit of an on-line correction protocol based on implanted markers and weekly portal imaging in external beam radiotherapy of prostate cancer. To compare the use of bony anatomy versus implanted markers for calculation of setup-error plus/minus prostate movement. To estimate the error reduction (and the corresponding margin reduction) by reducing the total error to ...

2013
Mika Kapanen Marko Laaksomaa Tapio Tulijoki Seppo Peltola Tuija Wigren Simo Hyödynmaa Pirkko-Liisa Kellokumpu-Lehtinen

BACKGROUND We estimated sufficient setup margins for head-and-neck cancer (HNC) radiotherapy (RT) when 2D kV images are utilized for routine patient setup verification. As another goal we estimated a threshold for the displacements of the most important bony landmarks related to the target volumes requiring immediate attention. METHODS We analyzed 1491 orthogonal x-ray images utilized in RT t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید