نتایج جستجو برای: radiotherapy intensity modulated
تعداد نتایج: 290062 فیلتر نتایج به سال:
Since the clinical implementation of novel rotational forms of intensity-modulated radiotherapy, a variety of planning studies have been published that reinforce the major selling points of the technique. Namely, comparable or even improved dose distributions with a reduction in both monitor units and treatment times, when compared with static gantry intensity-modulated radiotherapy. Although t...
The use of intensity-modulated radiation therapy (IMRT) has led to an increase in the number of complex fields that require measurement and comparison to calculated dose distributions in 2D. Current dose-evaluation techniques, including isodose line comparisons, displays of the dose difference between calculated and measured distributions, and distance-to-agreement (DTA) comparisons, are useful...
While modulated arc (mARC) capabilities have been available on Siemens linear accelerators for almost two years now, there was, until recently, only one treatment planning system capable of planning these treatments. The Eclipse treatment planning system now offers a module that can plan for mARC treatments. The purpose of this work was to test the module to determine whether it is capable of c...
In the Netherlands, about 2,300 people per year are diagnosed with a malignant tumor in the head and neck region. About 450 of them are referred to the Radboud University Nijmegen Medical Centre. Most of them undergo radiotherapy, either as a sole treatment, or in combination with surgery or chemotherapy. As part of the tailored radiation therapy most patients will be treated with Intensity Mod...
In inverse planning, the likelihood for the points in a target or sensitive structure to meet their dosimetric goals is generally heterogeneous and represents the a priori knowledge of the system once the patient and beam configuration are chosen. Because of this intrinsic heterogeneity, in some extreme cases, a region in a target may never meet the prescribed dose without seriously deteriorati...
When a brass compensator is set in a treatment beam, beam hardening may take place. This variation of the energy spectrum may affect the accuracy of dose calculation by a treatment planning system and the results of dose measurement of brass compensator intensity modulated radiation therapy (IMRT). In addition, when X-rays pass the compensator, scattered photons are generated within the compens...
The treatment delivery time of intensity-modulated radiation therapy (IMRT) with a multileaf collimator (MLC) is generally longer than that of conventional radiotherapy. In theory, removing the flattening filter from the treatment head may reduce the beam-on time by enhancing the output dose rate, and then reduce the treatment delivery time. And in practice, there is a possibility of delivering...
The purpose of this application note is to demonstrate the possibilities of the 2D-ARRAY seven29 from PTW in combination with the VeriSoft analysis software as a dosimetric verification tool of clinical IMRT fields. For this demonstration, the Varian IMRT system is used, which consists of the IMRT treatment planning system Eclipse Helios V7.2.24 and Varian Clinac accelerators, which are equippe...
A single calibration film method was evaluated for use with intensity-modulated radiation therapy film quality assurance measurements. The single-film method has the potential advantages of exposure simplicity, less media consumption, and improved processor quality control. Potential disadvantages include cross contamination of film exposure, implementation effort to document delivered dose, an...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید