Independence of calibration curves for EBT Gafchromic films of the size of high-energy X-ray fields.
The EBT Gafchromic radiochromic film is a relatively new product designed specifically for dosimetry in radiation therapy. Due to the weak dependence of its response on the photon energy (variations are below 10% in the 50 kVp-10 MVp range), the film is ideal for dosimetry when the photon energy spectrum may be changing or unknown. In order to convert a map of optical densities into a map of ab...
Irradiation of whole blood and blood components before transfusion is currently the only accepted method to prevent Transfusion-Associated Graft-Versus-Host-Disease (TA-GVHD). However, choosing the appropriate technique to determine the dosimetric parameters associated with blood irradiation remains an issue. We propose a dosimetric system based on the standard Fricke Xylenol Gel (FXG) dosimete...
Purpose: To evaluate the radiation attenuation properties of PC-ISO, a bio-compatible, sterilizable 3D printing material and its suitability for customized gynecologic (GYN) brachytherapy 15 applicators. Method: A custom radiochromic film dosimetry apparatus was 3D-printed in PC-ISO. The apparatus contained a single catheter channel and a slit to hold a radiochromic segment. A brachytherapy dos...
This study examined the response characteristics of three commercially available radiochromic films when exposed to low energy (50 kVp) X-rays. The aim was to evaluate the films for potential use in 2D dosimetry for a low-kV intraoperative radiotherapy (IORT) device known as the ‘Intrabeam’. Dose-response relationships were obtained for Gafchromic EBT, XR-RV2, and XR-QA film in water at several...
The location and field size of the incident X-ray beam in panoramic dental radiography cannot be ascertained visually most of the time. However, these parameters are needed for quality control and dosimetry determination. To alleviate this problem, we tested GafChromic XR-QA film on two panoramic systems. For each system, we used the length of a cross-sectional image of the incident beam and th...
Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek S...
The article provides a sequence of steps for using RISØ calorimeters calibration and subsequent use B3 radiochromic film dosimeters (GEX corporation) scanner measuring absorbed doses. Calibration was carried out with the help electron beam accelerator in range doses 3 – 40 kGy (measurement calorimeters). In course work, following out: dosimetry films calorimeters; plotting curve dosimetric film...
The authors have studied the feasibility of using three new high-sensitivity radiochromic devices in measuring the doses to peripheral points outside the primary megavoltage photon beams. The three devices were GAFCHROMIC® EBT film, prototype Low Dose (LD) Film, and prototype LD Card. The authors performed point dosimetry using these three devices in water-equivalent solid phantoms at x = 3,5,8...