نتایج جستجو برای: radial dose function

تعداد نتایج: 1533152  

2013
J Adamson Y Yang L Rankine J Newton J Adamovics O Craciunescu M Oldham

We describe a method to directly measure the radial dose and anisotropy functions of brachytherapy sources using polyurethane based dosimeters read out with optical CT. We measured the radial dose and anisotropy functions for a Cs-137 source using a PRESAGE® dosimeter (9.5cm diameter, 9.2cm height) with a 0.35cm channel drilled for source placement. The dosimeter was immersed in water and irrad...

2002
Timothy D. Solberg John J. DeMarco Geoffrey Hugo Robert E. Wallace

Monte Carlo calculations and TLD measurements have been performed for the purpose of characterizing dosimetric properties of new commercially available brachytherapy sources. All sources tested consisted of a solid core, upon which a thin layer of 125I has been adsorbed, encased within a titanium housing. The PharmaSeed BT-125 source manufactured by Syncor is available in silver or palladium co...

Journal: :journal of medical signals and sensors 0
hamid-reza sadoughi shahrokh nasseri mahdi momennezhad hamid-reza sadeghi mohammad hossein bahreyni

radiotherapy dose calculations can be evaluated by monte carlo (mc) simulations with acceptable accuracy for dose prediction in complicated treatment plans. in this work, standard, livermore and penelope electromagnetic (em) physics packages of geant4 application for tomographic emission (gate) 6.1 were compared versus monte carlo n-particle extended (mcnpx) 2.6 in simulation of 6 mv photon lin...

Journal: :Heart 2002
X J Jiang M F O'Rourke W Q L Jin L S Liu C W Li P C Tai X C Zhang S Z Liu

OBJECTIVE To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. DESIGN Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104-0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...

2002
X J Jiang S Z Liu

Objective: To establish through analysis of the radial pressure pulse waveform the dose dependent effects of glyceryl trinitrate (GTN) on properties of different blood vessels. Design: Radial pulse waveform was measured in randomised order before, during a five hour application of a GTN patch delivering 0.104–0.625 mg/h, and for two hours after patch removal. The radial pressure waveform (Milla...

Journal: :Medical physics 2000
A S Meigooni D M Gearheart K Sowards

125I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the Best 125I source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally determined, following the AAPM Task Group 43 recommendation...

2004
Y. Takahashi A. Ito M. Yoshioka A. Kuwabara T. Yamashita

High dose rate brachytherapy has attained the good local control for cervix cancer because radioactive source can be put close to tumors, resulting in increasing the dose delivery per one fraction. However, quality assurance must be accompanied to reduce severe complication. We verified the dose distribution around the source by comparing measured dose with calculated dose by Radiation Therapy ...

1998
Klaus Hahn Thomas Waschulzik

A connectionist model made up of a combination of RBF networks is proposed the model decomposes multivalued dependencies into local single valued functions theory and applications are presented

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید