نتایج جستجو برای: potentiometric determination

تعداد نتایج: 253339  

Carbon paste electrode was modified by disodium 2,4-diamino-7-methylbenzo[g] pteridine-5,10-dioxide to fabricate a sensor for potentiometric determination of vanadyl ion (VO2+) in aqueous medium. The new ligand was synthesized in three steps with high yield. The optimal composition of the carbon paste was made of graphite powder (64.5%), ionophore (16.6%), paraffin oil (17.8%), a...

2013
Larisa Lvova Pierluca Galloni Barbara Floris Ingemar Lundström Roberto Paolesse Corrado Di Natale

5,10,15,20-Tetraferrocenyl porphyrin, H2TFcP, a simple example of a donor-acceptor system, was tested as ligand for the development of a novel multi-transduction chemical sensors aimed at the determination of transition metal ions. The fluorescence energy transfer between ferrocene donor and porphyrin acceptor sub-units was considered. The simultaneously measured optical and potentiometric resp...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2001
M Shamsipur T Poursaberi S Rouhani K Niknam H Sharghi M R Ganjali

A PVC-membrane electrode based on a recently synthesized 18-membered macrocyclic diamide is presented. The electrode reveals a Nernstian potentiometric response for Co2+ over a wide concentration range (2.0 x 10(-6)-1.0 x 10(-2) M). The electrode has a response time of about 10 s and can be used for at least 2 months without any divergence. The proposed sensor revealed very good selectivities f...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2004
Jahan-Bakhsh Raoof Reza Ojani Abolfazl Kiani

Silver ion can perturb the Belousov-Zhabotinskii (B-Z) oscillating chemical reaction. Therefore, the B-Z oscillating system was applied in the determination of silver ion by using a platinum wire as an indicator electrode in the potentiometric method. The amplitude of the potentiometric oscillation increased linearly in proportion to [Ag+] in the range of 9.42 x 10(-6) M to 2.54 x 10(-4) M, wit...

Journal: :ChemElectroChem 2022

Abstract The decentralisation of accurate determination the ammonium ion (NH 4 + ) is relevant for environmental monitoring (i. e., nitrogen cycle) and certain clinical applications (e. g., kidney liver diseases). Potentiometric ionophore‐based sensors are one alternative these purposes in terms versatile implementation, though potassium (K known to be a major source interference. We herein inv...

Journal: :Clinical chemistry 1984
P Bijster K L Vink

We measured the emf of NaCl solutions (120-160 mmol/L) with a home-built cell in steady-state and with some commercial direct potentiometric analyzers about 20 s after the sample is introduced into the instrument. We compared the results with the theoretical sodium ion activity calculated according to different thermodynamic theories. The slope of the calibration graph was calculated with and w...

2010
Robert Zakrzewski R. Zakrzewski

The possibilities of application of iodine as a titrant in determination of sulfur compounds have been presented. The influence of the reaction medium, the nature of compounds, and the thiol–thione tautomerism on the reaction stoichiometry of sulfur compounds with iodine has been discussed. The conditions of volumetric titration with visual and potentiometric end-point detection and coulometric...

Journal: :Journal of pharmaceutical and biomedical analysis 2004
Adriana M Pimenta Alberto N Araújo Maria Conceição B S M Montenegro Celio Pasquini Jarbas J R Rohwedder Ivo M Raimundo

Two quasi-independent methods for potentiometric and optical determination of chloride were simultaneously implemented in a flow system, providing real-time assessment of the quality of results. A potentiometric and an optical polymeric membrane doped with the same indium(III) octaethyl-porphyrin were used as sensor ionophore. The working mechanism and the analytical characteristics of these po...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2002
Khalil Farhadi Ramin Maleki

A novel triiodide ion-selective electrode based on a clotrimazole-triiodide ion pair as a membrane carrier was prepared. It has a linear response to triiodide from 8 x 10(-6) to 5 x 10(-3) M with a slope of -68.9 mV per decade and a detection limit of 5 x 10(-6) M. The electrode response is independent of the pH of the solution in the pH range 2-9. It has a very short response time and can be u...

2012
J. Wang H. X. Zhao L. P. Du H. Cai P. Wang

An enzyme-metal-insulator-silicon (EMIS) structured chemical sensor based on photovoltage technology is constructed for potentiometric biosensing of glucose in a flow-injection analysis (FIA) system. To enhance the sensibility of the sensor to glucose, an ultra-thin (60 nm) film of polypyrrole (PPy)-glucose oxidase (GOD) is formed as the glucose-sensitive membrane through a simple electropolyme...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید