نتایج جستجو برای: potentiometric detection

تعداد نتایج: 568557  

Journal: :Talanta 2021

The developments of alternative signal readout strategies for the ion-selective electrodes (ISEs) are necessary in order to break through limitation Nernst equation. In this work, a simple, convenient and easily operated strategy based on non-enzymatic amperometric measurement H2O2 is proposed read out potentiometric responses ISEs. carried two compartment electrochemical cell configuration con...

Journal: :Analytical chemistry 2013
Ewa Grygolowicz-Pawlak Gastón A Crespo Majid Ghahraman Afshar Günter Mistlberger Eric Bakker

Potentiometric sensors that exhibit a non-Hofmeister selectivity sequence are normally designed by selective chemical recognition elements in the membrane. In other situations, when used as detectors in separation science, for example, membranes that respond equally to most ions are preferred. With so-called liquid membranes, a low selectivity is difficult to accomplish since these membranes ar...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2004
Hamid R Zare Masoud Salavati-Niassary Farkhondeh Memarzadeh Mohammad Mazloum Navid Nasirizadeh

A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0...

A. Islamnezhad E. D. Zobairi Sh. Keyvan,

A nanocomposite membrane Cu2+ ion-selective electrode has been constructed using a new compound ethyl 1,2,3,4-tetrahydro-4-(4-methoxyphenyl)-6-methyl-2-oxopyrimidine-5-carboxylat (ETMOC) as a neutral ionophore. The electrode works properly. It responds to Cu2+ ion with a sensitivity of 29.5 ± 0.2 mV/decade over the range 1.0 × 10−9 to 5.0 × 10−1M at p...

Ali Beyramabadi Esmat Shojaeia Hossein Behmadi Mahboubeh Masrournia,

The strontium ion, in water-soluble forms, is one of the major pollutant in drinking water. Therefore, a simple, rapid, selective, and sensitive potentiometric carbon paste electrode was developed to measure strontium ion in real samples with complex matrices. To prepare the potentiometric sensor, a synthetic ligand ((E)-4-(((2-amino-4-chlorophenyl)imino)methyl)-5-(hydroxymethyl)-2-methyl pyrid...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه رازی - دانشکده علوم 1390

abstract ion selective electrodes (ises) are electrochemical sensors that respond selectivity to the activity of ionic species. an ion-selective electrode is an electrochemical device that uses a thin selective membrane or film as the recognition element, and is an electrochemical half-cell equivalent to other half-cells of the zeroth (inert metal in a redox electrolyte). in common methods o...

2015
Ewa Jaworska Krzysztof Maksymiuk

The possibility of using disposable plastic-carbon potentiometric sensors as enzyme biosensors was examined. Urease enzyme was immobilized on poly(vinyl chloride) based Hor NH4-selective membranes using cellulose acetate. This approach has resulted in a potentiometric response on changing the pH of the solution or NH4 ion content due to an enzymatic reaction that occurs between urease and urea....

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید