نتایج جستجو برای: phantom spect imaging system

تعداد نتایج: 2623550  

Journal: :Journal of nuclear medicine : official publication, Society of Nuclear Medicine 1998
G L Zeng G T Gullberg C Bai P E Christian F Trisjono E V Di Bella J W Tanner H T Morgan

UNLABELLED This article demonstrates resolution recovery in 18F SPECT image reconstruction by using an iterative algorithm that corrects for the system geometric response. METHODS Patient and phantom studies were performed using a Picker PRISM 3000 three-detector SPECT system (Picker International, Inc., Cleveland, OH) to image 18F with 511 keV collimators. A measured point response function ...

Journal: :Journal of X-ray science and technology 2015
Guohe Wang Bin Zhang Yichen Ding Yun He Jingsong Chen Yanye Lu Xiaoyun Jiang Junwei Shi Jing Bai Qiushi Ren Changhui Li

Nowadays multi-modality imaging has gained great interest in biology research by offering complementary information. In this paper, a modularly designed fluorescence molecular tomography (FMT) system has been developed, which can be not only used as a standalone imaging device, but also feasibly integrated with other imaging modalities, such as X-ray computed tomography (X-CT), single photon em...

Journal: :Medical principles and practice : international journal of the Kuwait University, Health Science Centre 2004
Nasser Ballani Geoff Dougherty

OBJECTIVE To devise and validate a method of estimating accurately myocardial wall thickness from cardiac images acquired with single photon emission tomography (SPECT). MATERIALS AND METHODS We simulated the imaging process by convolving a spatial resolution function, experimentally determined for a clinical SPECT system, with rectangular profiles mimicking the myocardial walls for different...

Journal: :iranian journal of medical physics 0
faraz kalantari phd student, medical physics dept., faculty of medical sciences, tarbiat modares university, tehran, iran hossein rajabi associate professor, medical physics dept., faculty of medical sciences, tarbiat modares university, tehran, iran nahid yaghoobi assistant professor, nuclear medicine dept., rajaei heart center, iran university of medical sciences, tehran, iran ahmad bitarafan assistant professor, nuclear medicine dept., rajaei heart center, iran university of medical sciences, tehran, iran

introduction: it is a common protocol to use 201tl for the rest and 99mtc for the stress cardiac spect imaging. theoretically, both types of imaging may be performed simultaneously using different energy windows for each radionuclide. however, a potential limitation is the cross-contamination of scattered photons from 99mtc and collimator x-rays into the 201tl energy window. we used a middle en...

Journal: :asia oceania journal of nuclear medicine and biology 0
yasuyuki takahashi department of nuclear medicine technology, gunma prefectural college of health sciences, maebashi, japan masao miyagawa department of radiology, ehime university graduate school of medicine, toon, japan yoshiko nishiyama department of radiology, ehime university graduate school of medicine, toon, japan naoto kawaguchi department of radiology, ehime university graduate school of medicine, toon, japan hayato ishimura department of radiological technology, ehime university hospital, toon, japan teruhito mochizuki department of radiology, ehime university graduate school of medicine, toon, japan

objective(s): the energy resolution of a cadmium-zinc-telluride (czt) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional anger type detector which is 10%. also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. in this study, we used a semiconductor detector and examined the ef...

2014
Yasushi Yamamoto Masahisa Onoguchi Kazunori Kawakami Masuo Haramoto Rei Wake Jun Horiguchi Hajime Kitagaki

OBJECTIVE We examined the difference of the effect by data to revise a gamma camera difference. The difference-correction method of the camera is incorporated in eZIS analysis. METHODS We acquired single photon emission computed tomography (SPECT) data from the three-dimensional (3D) Hoffman brain phantom (Hoffman), the three-dimensional brain phantom (3D-Brain), Pool phantom (pool) and from ...

2015
Eser Erim Turkan Ertay Ismail Evren Mine Eren Cengiz Tasci Hatice Durak

Movement of the patient during myocardial perfusion SPECT leads to some artifacts that make the interpretation difficult. In this study, myocardial perfusion imaging protocol was performed on a cardiac phantom and SPECT was performed by simulating patient movements. A lesion model with dimensions of 1.2 × 2 × 2 cm was created on the inferoseptal wall of the cardiac phantom. Imaging was done in ...

2015
Oliver S. Grosser Dennis Kupitz Juri Ruf Damian Czuczwara Ingo G. Steffen Christian Furth Markus Thormann David Loewenthal Jens Ricke Holger Amthauer Li Zeng

BACKGROUND Hybrid imaging combines nuclear medicine imaging such as single photon emission computed tomography (SPECT) or positron emission tomography (PET) with computed tomography (CT). Through this hybrid design, scanned patients accumulate radiation exposure from both applications. Imaging modalities have been the subject of long-term optimization efforts, focusing on diagnostic application...

Journal: :Annals of nuclear medicine 2000
K Suga N Matsunaga Y Kawakami M Furukawa

PURPOSE A phantom study was conducted to evaluate the feasibility of body contour definition with Compton scatter photons from external sources of technetium-99m pertechnetate (Tc-99m) to create a fusion image of CT and SPECT images. METHODS External sources of 1 mCi (37 MBq) Tc-99m were placed on each collimator, and body-contour SPECT images were obtained with an energy window of 100 keV +/...

2006
Yi-Chun Chen

A novel small-animal SPECT imager, FastSPECT II, was recently developed at the Center for Gamma-Ray Imaging. FastSPECT II consists of two rings of eight modular scintillation cameras and list-mode data-acquisition electronics that enable stationary and dynamic imaging studies. The instrument is equipped with exchangeable aperture assemblies and adjustable camera positions for selections of magn...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید