نتایج جستجو برای: phantom ct mtf phantom autocad modulation

تعداد نتایج: 300098  

Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...

Journal: :Annals of nuclear medicine 2000
K Suga N Matsunaga Y Kawakami M Furukawa

PURPOSE A phantom study was conducted to evaluate the feasibility of body contour definition with Compton scatter photons from external sources of technetium-99m pertechnetate (Tc-99m) to create a fusion image of CT and SPECT images. METHODS External sources of 1 mCi (37 MBq) Tc-99m were placed on each collimator, and body-contour SPECT images were obtained with an energy window of 100 keV +/...

M. Amoui, M. Hosntalab, M.R. Teimoori Sichani, Sh. Akhlaghpoor,

Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...

2017
Syahir Mansor Elisabeth Pfaehler Dennis Heijtel Martin A. Lodge Ronald Boellaard Maqsood Yaqub

PURPOSE In longitudinal oncological and brain PET/CT studies, it is important to understand the repeatability of quantitative PET metrics in order to assess change in tracer uptake. The present studies were performed in order to assess precision as function of PET/CT system, reconstruction protocol, analysis method, scan duration (or image noise), and repositioning in the field of view. METHO...

2017
Daniel F. Craft Rebecca M. Howell

PURPOSE Patient-specific 3D-printed phantoms have many potential applications, both research and clinical. However, they have been limited in size and complexity because of the small size of most commercially available 3D printers as well as material warping concerns. We aimed to overcome these limitations by developing and testing an effective 3D printing workflow to fabricate a large patient-...

Journal: :iranian journal of radiation research 0
s. senthilkumar department of radiotherapy, madurai medical college and govt. rajaji hospital, maduari-625 020, india

background: the purpose of this study is to fabricate inexpensive in-house low cost homogeneous and heterogeneous human equivalent thorax phantom and assess the dose accuracy of the treatment planning systems (tps) calculated values for different lung treatment dosimetery. it is compared with thermoluminescent dosimeter (tld) measurement. materials and methods: homogeneous and heterogeneous tho...

Introduction: Quality assurance in Computed tomography (CT) centers in developing countries are largely hindered by the unavailability of CT phantoms. The development of a local CT phantom for the measurement of organ radiation absorbed dose is therefore requisite. Material and Methods: Local CT phantoms were designed to meet the standard criteria of 32 cm diameter for body, 16 cm diameter for...

Journal: :Medical physics 2009
David W Nelms Hemant I Shukla Earl Nixon John E Bayouth Ryan T Flynn

PURPOSE Dead detectors due to manufacturing defects or radiation damage in the electronic portal imaging devices (EPIDs) used for cone-beam computed tomography (CBCT) can lead to image degradation and ring artifacts. In this work three dead detector correction methods were assessed using megavoltage CBCT (MVCBCT) as a test system, with the goals of assessing the relative effectiveness of the th...

2016
Kerry A. Greene‐Donnelly Kent M. Ogden

The American College of Radiology (ACR) Computed Tomography (CT) Accreditation Program requires submission of phantom scans acquired with the ACR accreditation phantom. There is a known issue with some wide-beam scanners in which the Hounsfield unit (HU) value of water may be correct when using the scanner manufacturer's phantom, but will be out of range in some scan modes when scanning the acc...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید