نتایج جستجو برای: ph sensor
تعداد نتایج: 353417 فیلتر نتایج به سال:
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
This paper introduces different data fusion methods which are used for an electrochemical measurement using a sensor array. In this study, we used ruthenium dioxide sensing membrane pH electrodes to form a sensor array. The sensor array was used for detecting the pH values of grape wine, generic cola drink and bottled base water. The measured pH data were used for data fusion methods to increas...
A reference electrode fabricated by means of thick-film technique is deposited onto a silicon substrate and combined with a thin-film pH sensor to a “hybrid” chip system. To evaluate the suitability of this combination, first investigations were carried out. The characteristics of the thin-film pH sensor were studied towards the thick-film Ag/AgCl reference electrode. Measurements were performe...
The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6to 1.0×10-1M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two mont...
Luminal amino acids and lack of luminal acidity as a result of acid neutralization by intragastric foodstuffs are powerful signals for acid secretion. Although the hormonal and neural pathways underlying this regulatory mechanism are well understood, the nature of the gastric luminal pH sensor has been enigmatic. In clinical studies, high pH, tryptic peptides, and luminal divalent metals (Ca(2+...
New aza-BODIPY indicators which cover the pH scale from 1.5 to 13 are presented. The new indicators feature absorption/emission bands in the red/near-infrared (NIR) spectral region, exhibit high molar absorption coefficients (∼ 80,000 M(-1) cm(-1)) and show good quantum yields (∼20%). All dyes represent promising building blocks for the development of a broad-range sensor for various pH ranges....
Automation of pH Measurement Using a Flow-Through Type Differential pH Sensor System Based on pH-FET
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید