نتایج جستجو برای: pedicle screw

تعداد نتایج: 19650  

2014
Martin James Wood Jason McMillen

OBJECTIVE This study retrospectively assessed the accuracy of placement of lumbar pedicle screws placed by a single surgeon using a minimally-invasive, intra-operative CT-based computer navigated technique in combination with continuous electromyography (EMG) monitoring. The rates of incorrectly positioned screws were reviewed in the context of the surgeon's experience and learning curve. MET...

2017
Jun Xuan Jian Chen Hui He Hai-Ming Jin Di Zhang Yao-Sen Wu Nai-Feng Tian Xiang-Yang Wang

Thoracic cortical bone trajectory (CBT) screw fixation can maximize the thread contact with cortical bone, and it is 53.8% higher than that of the traditional pedicle screws. Moreover, it can also enable less tissue dissection and retraction for reduced muscle disruption.Eighty pediatric patients are divided into 4 age groups and their thoracic vertebrae are analyzed on computed tomography (CT)...

2012
Sang-Mok Yoon Jin-Wook Baek Dae-Hyun Kim

OBJECTIVE To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities. METHODS After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft ...

2017
Guoli Song Hua Bai Yiwen Zhao Xiaozhuang Liu

Pedicle screw insertion has been a standard processes for stabilizing the spine [1]. Spinal surgery can be classified as either minimally invasive or open, based on differences in the size of incisions: minimally invasive surgery implants the pedicle screw based on intraoperative fluoroscopic images to ensure the entry point and trajectory, and open surgery implants the pedicle screw based on i...

Journal: :Neurology India 2005
S C Zeiller J Lee M Lim A R Vaccaro

The use of pedicle screw instrumentation in the spine has evolved over the last two decades. The initial use of pedicle screws began in the lumbar spine. As surgeons have become more comfortable with the complex anatomy required for accurate screw placement, the use of pedicle instrumentation has evolved to include their use in the thoracolumbar and thoracic spine. The impetus behind their incr...

Journal: :JBJS reviews 2017
I David Kaye Srinivas K Prasad Alex R Vaccaro Alan S Hilibrand

P edicle screw fixation for spinal stabilization is now commonplace in spine surgery. Traditionally, pedicle screws are placed through a trajectory in which screw insertion utilizes a transpedicular path through the axis of the pedicle, either paralleling the end plate, as in the straightforward trajectory, or following the anatomic axis of the pedicle with an approximately 22° cephalocaudal tr...

Journal: :Ortopedia, traumatologia, rehabilitacja 2009
Piotr Harasymczuk Tomasz Kotwicki Aleksander Koch Andrzej Szulc

BACKGROUND In recent years pedicle screw based constructs have been increasingly used in the operative management of scoliosis. The current principles of screw placement are based on normal anatomy and therefore may not be applicable in cases of severe vertebral deformity due to torsion. The aim of this study was to evaluate the usefulness of computer tomography (CT) in preoperative planning an...

Journal: :Acta medica Okayama 2010
Yoshihisa Sugimoto Yasuo Ito Masao Tomioka Tetsuya Shimokawa Yasuyuki Shiozaki Tetsuro Mazaki Masato Tanaka

Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 ve...

2014
Ilkka Helenius Mikko Mattila Tuomas Jalanko

OBJECTIVES Untreated severe scoliosis is associated with increased mortality and remains a significant surgical challenge. Few studies have reported mortality after the surgical treatment of severe scoliosis beyond a 2-year follow-up. The objectives of this study were to evaluate mortality beyond standard 2-year follow-up and compare radiographic outcomes using hybrid or pedicle screw instrumen...

2016
Kunpeng Li Wen Zhang Dan Liu Hui Xu Wei Geng Dawei Luo Jinzhu Ma

BACKGROUND Use of a pedicle screw at the level of fracture, also known as an intermediate screw, has been shown to improve clinical results in managing thoracolumbar(TL) fractures, but there is a paucity of powerful evidence to support the claim. The aim of this study was to compare outcomes between pedicle screw fixation combined with intermediate screw at the fracture level and conventional p...

200420052006200720082009201020112012201320142015201620172018201920202021202220230500100015002000

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید