Journal: :International Journal of Medical Sciences 2004
Joseph A. Both Todd Pawlicki

This work is a report on the commissioning of low energy electron beams of a medical linear accelerator for Monte Carlo dose calculation using NXEGS software (NXEGS version 1.0.10.0, NX Medical Software, LLC). A unique feature of NXEGS is automated commissioning, a process whereby a combination of analytic and Monte Carlo methods generates beam models from dosimetric data collected in a water p...

Journal: :Journal of Ayub Medical College, Abbottabad : JAMC 2010
Saeed Ahmad Buzdar M Afzal Andrew Todd-Pokropek

BACKGROUND In radiotherapy treatment, the calculation of radiation dose distribution in target volume lead to an optimum set of planning parameters. This worked has been aimed to compare two photon beam dose calculation algorithms in the Oncentra Treatment Planning system for Varian Linear Accelerator, to assure the quality of treatment planning. METHODS Monitor Units to be delivered on norma...

2009
Massimo Pasquino Valeria Casanova Borca Santi Tofani F. Ozzello

This paper investigates the accuracy of the two available calculation algorithms of the Oncentra MasterPlan three-dimensional treatment planning system (TPS)-- the pencil beam method and collapsed-cone convolution--in modeling the Varian enhanced dynamic wedge (EDW). Measurements were carried out for a dual high energy (6-15 MV) Varian DHX-S linear accelerator using ionization chambers for beam...

H. Gholamhoseinian, M. Momennezhad, M.T. Bahreyni Toosi, R. Sadeghi, Sh. Nasseri,

Background: The presence of a wedge filter in the beam trajectory can modify the beam quality and cause some changes in the dosimetry parameters which are usually difficult to be measured directly and accurately. Material and Methods: In this study the MCNP-4C Monte Carlo code was used to simulate the 9 MV photon beam generated by a linear accelerator. Upon getting a good agreement bet...

Journal: :journal of biomedical physics and engineering 0
m ebrahimi loushab a a mowlavi physics department, faculty of sciences, ferdowsi university of mashhad, mashhad, iran m h hadizadeh physics department, school of sciences, hakim sabzevari university, sabzevar, iran 3ictp, associate federation, medicalسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university) r izadi 1physics department, faculty of sciences, ferdowsi university of mashhad, mashhad, iranسازمان اصلی تایید شده: دانشگاه حکیم سبزواری (hakim sabzevari university) s b jia physics department, university of bojnord, bojnord, iranسازمان اصلی تایید شده: دانشگاه فردوسی (ferdowsi university)

normal 0 false false false en-us x-none fa microsoftinternetexplorer4 background: in radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness. metho...

2007
Bruce A Faddegon Joseph Perl Makoto Asai

Two Monte Carlo systems, EGSnrc and Geant4, were used to calculate dose distributions in large electron fields used in radiotherapy. Source and geometry parameters were adjusted to match calculated results with measurement. Both codes were capable of accurately reproducing the measured dose distributions of the 6 electron beams available on the accelerator. Depth penetration was matched to 0.1 ...

Journal: :Medical dosimetry : official journal of the American Association of Medical Dosimetrists 2003
Paul J Keall Jeffrey V Siebers Robert Jeraj Radhe Mohan

The high density and atomic number of hip prostheses for patients undergoing pelvic radiotherapy challenge our ability to accurately calculate dose. A new clinical dose calculation algorithm, Monte Carlo, will allow accurate calculation of the radiation transport both within and beyond hip prostheses. The aim of this research was to investigate, for both phantom and patient geometries, the capa...

  Abstract   Background : Beam-hardening artifacts in CT image set of patient with a hip prosthesis cause difference between dose distributions resulted by treatment planning system (TPS) algorithms and actual dose distribution in patient body. In this study, dose distributions of TPS algorithms were compared with the results of Monte Carlo simulations of Titanium and Steal as a h...

ژورنال: سنجش و ایمنی پرتو 2018

Monte Carlo method is the most accurate method for simulation of radiation therapy equipment. The linear accelerators (linac) are currently the most widely used machines in radiation therapy centers. Monte Carlo modeling of the Siemens Primus linear accelerator in 6 MeV beams was used. Square field size of 10 × 10 cm2 produced by the jaws was compared with TLD. Head simulation of Siemens accele...

2008
Ye Angela Hu Haijun Song Zhe Chen Sumin Zhou Fang‐Fang Yin

The electron Monte Carlo (eMC) dose calculation algorithm of the Eclipse treatment planning system is based heavily upon Monte Carlo simulation of the linac head and modeling of the linac beam characteristics with minimal measurement of beam data. Commissioning of the eMC algorithm on multiple identical linacs provided a unique opportunity to systematically evaluate the algorithm with actual me...