نتایج جستجو برای: modified screen printed electrode

تعداد نتایج: 402482  

Journal: :Journal of Electrochemical Science and Engineering 2022

The current work aimed to fabricate a screen-printed graphite electrode (SPGE) modified by MnO2 nanorods (MnO2 NRs) for sensing hydrazine. Thus, facile protocol was adopted construct the that were subsequently applied modify SPGE surface directly. As-synthesized NRs/SPGE sensor exhibited strong behavior towards hydrazine, with large peak and small oxidation potential. This electrochemical in op...

2013
Se Yun Kim Suk Jun Kim Sang Soo Jee Jin Man Park Keum Hwan Park Sung Chan Park Eun Ae Cho Jun Ho Lee In Yong Song Sang Mock Lee In Taek Han Ka Ram Lim Won Tae Kim Ju Cheol Park Jürgen Eckert Do Hyang Kim Eun-Sung Lee

Metallic glass (MG) assists electrical contact of screen-printed silver electrodes and leads to comparable electrode performance to that of electroplated electrodes. For high electrode performance, MG needs to be infiltrated into nanometer-scale cavities between Ag particles and reacts with them. Here, we show that the MG in the supercooled state can fill the gap between Ag particles within a r...

Journal: :International Journal of Health Sciences (IJHS) 2022

A sensitive and selective electrochemical sensor based on screen-printed carbon electrode (SPCE) for detecting paracetamol has been studied. The SPCE performance was observed using cyclic voltammetry (CV) in 0.1 M phosphate buffer solution at various pH. measurement done a potential range from -0.75 V to +1 room temperature. response of shows that can be detected clearly its oxidation (0.63 V) ...

Journal: :The Analyst 2011
Eman Y Z Frag Gehad G Mohamed F A Nour El-Dien Marwa E Mohamed

This paper describes the development of screen-printed (SPE) and carbon paste (CPE) sensors for the rapid and sensitive quantification of naphazoline hydrochloride (NPZ) in pharmaceutical formulations. This work compares the electroactivity of conventional carbon paste and screen-printed carbon paste electrodes towards potentiometric titration of NPZ. The repeatability and accuracy of measureme...

Journal: :Electroanalysis 2022

An enzymatic biofuel cell is integrated on a screen-printed electrode as basis for self-powered biosensor. A glucose/O2 consisting of pyrroloquinoline quinone-dependent glucose dehydrogenase embedded within an Os-complex modified redox polymer bioanode to oxidize and non-limiting bilirubin oxidase-based gas diffusion biocathode in the direct-electron transfer regime reduction O2 showed glucose-...

2013
Cristina Fernández-Blanco Álvaro Colina Aránzazu Heras

A new controlled current multipulse methodology has been developed to modify the screen-printed electrode surface with silver nanoparticles (AgNPs). Spectroelectrochemistry has provided not only information about the type of nanoparticles (NPs) deposited on the electrode surface, but also about the electrosynthesis process. Small NPs without plasmon band are initially generated. Next, these nuc...

2010
Vojtěch Polan Jan Soukup Karel Vytřas

The described glucose biosensor is based on a screen-printed carbon electrode (SPCE) modified by rhodium dioxide, which functions as a mediator. The electrode is further modified by the enzyme glucose dehydrogenase, which is immobilized on the electrode's surface through electropolymerization with m-phenylenediamine. The enzyme biosensor was optimized and tested in model glucose samples. The bi...

2008
Libuse Trnkova Vojtech Adam Jaromir Hubalek Petr Babula Rene Kizek

Chloride ion sensing is important in many fields such as clinical diagnosis, environmental monitoring and industrial applications. We have measured chloride ions at a carbon paste electrode (CPE) and at a CPE modified with solid AgNO₃, a solution of AgNO₃ and/or solid silver particles. Detection limits (3 S/N) for chloride ions were 100 μM, 100 μM and 10 μM for solid AgNO₃, solution of AgNO₃ an...

نمودار تعداد نتایج جستجو در هر سال