1997
Yoko Kishi

Inductively coupled plasma mass spectrometry (ICP-MS) is an analytical technique that performs elemental analysis with excellent sensitivity and high sample throughput. The ICP-MS instrument employs a plasma (ICP) as the ionization source and a mass spectrometer (MS) analyzer to detect the ions produced. It can simultaneously measure most elements in the periodic table and determine analyte con...

Journal: :Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 2005
Periasamy Manoravi Mathew Joseph Natrajan Sivakumar Rajagopalan Balasubramanian

A reflectron time-of-flight mass spectrometer (RTOFMS) with a laser ablation ion source was used to determine the isotopic ratio of 10B/11B present in boric acid solutions, using graphite as the matrix. The atom % 10B values obtained were within +/-1% of the actual ones. The determination of the boron isotopic ratio using this method is, in comparison to other methods, faster, less expensive an...

Journal: :British Journal of Anaesthesia 1974

Journal: :Review of Scientific Instruments 1985

1999
Michalis Velegrakis George E. Froudakis Stavros C. Farantos

A laser vaporisation source and a time-of-flight mass spectrometer are used for the production and detection of TiArn Ž . clusters. Parallel, density functional theory DFT calculations assist in extracting the structures of the first members of the series. The mass spectrum is dominated by one intense line of TiAr , for which the DFT calculations predict a regular 6 octahedron. q 1999 Elsevier ...

Journal: :Journal of the Mass Spectrometry Society of Japan 1958

Journal: :Vacuum and Surface Science 2019

2005
Ş. Şentürk

The ionization region of the ToF mass spectrometer having the WileyMcLaren geometry was further enlarged on the basis of the Milani–de Heer criteria. The enlarging limits the use of the spectrometer to small cluster range as a result of mass resolution decrease at great deal amount. However the spectrometer is promising for the electron-cluster interaction studies. Key wordsEnlarged ionization ...

Journal: :The Analyst 2015
T F Limero E G Nazarov M Menlyadiev G A Eiceman

The air quality monitor (AQM), which included a portable gas chromatograph (GC) and a detector was interfaced to a mass spectrometer (MS) by introducing flow from the GC detector to the atmospheric pressure ion source of the MS. This small GC system, with a gas recirculation loop for carrier and detector make-up gases, comprised an inlet to preconcentrate volatile organic compounds (VOCs) in ai...