نتایج جستجو برای: keywords motion correction

تعداد نتایج: 2309005  

2011
Andre Z. Kyme Victor W. Zhou Steven R. Meikle Clive Baldock Roger R. Fulton

Positron emission tomography (PET) is a non-invasive molecular imaging technique using positron-emitting radioisotopes to study functional processes within the body. High resolution PET scanners designed for imaging rodents and non-human primates are now commonplace in preclinical research. Brain imaging in this context, with motion compensation, can potentially enhance the usefulness of PET by...

2014
Nii O Addy Jieying Luo R Reeve Ingle Bob S Hu Dwight G Nishimura

PURPOSE To develop a method for acquiring whole-heart 3D image-based navigators (iNAVs) with isotropic resolution for tracking and correction of localized motion in coronary magnetic resonance angiography (CMRA). METHODS To monitor motion in all regions of the heart during a free-breathing scan, a variable-density cones trajectory was designed to collect a 3D iNAV every heartbeat in 176 ms wi...

2001
A. D. Armour

We estimate the correction to the Cooper-pair box energy level splitting due to the quantum motion of a coupled micromechanical gate electrode. While the correction due to zero-point motion is very small, it should be possible to observe thermal motion-induced corrections to the photon-assisted tunneling current.

2009
J. Liu T. D. Nguyen P. Spincemaille N. C. Codella M. R. Prince Y. Wang

INTRODUCTION Free-breathing cardiac cine imaging with respiratory and cardiac self-gating provides flexibility and convenience for patient scans. Here we propose a 3D radial cardiac cine imaging technique that improves upon self-gating by adding 3D respiratory motion correction. The 3D respiratory motion signals are derived from multiple projections through the data used for image reconstructio...

2018
Joris D. van Dijk Jorn A. van Dalen Mohamed Mouden Jan Paul Ottervanger Siert Knollema Cornelis H. Slump Pieter L. Jager

BACKGROUND Correction of motion has become feasible on cadmium-zinc-telluride (CZT)-based SPECT cameras during myocardial perfusion imaging (MPI). Our aim was to quantify the motion and to determine the value of automatic correction using commercially available software. METHODS AND RESULTS We retrospectively included 83 consecutive patients who underwent stress-rest MPI CZT-SPECT and invasiv...

2009
Chuanyong Bai Jamshid Maddahi Joel Kindem Richard Conwell Michael Gurley Rex Old

BACKGROUND In cardiac SPECT perfusion imaging, motion correction of the data is critical to the minimization of motion introduced artifacts in the reconstructed images. Software-based (data-driven) motion correction techniques are the most convenient and economical approaches to fulfill this purpose. However, the accuracy is significantly affected by how the data complexities, such as activity ...

2005
Arman Rahmim

With the arrival of increasingly higher resolution PET systems, small amounts of motion can cause significant blurring in the images, compared to the intrinsic resolutions of the scanners. In this work, we have reviewed advanced correction methods for the three cases of (i) unwanted patient motion, as well as motions due to (ii) cardiac and (iii) respiratory cycles. For the first type of motion...

2013
Ashrani Aizzuddin Abd. Rahni Emma Lewis Kevin Wells

Compensation for respiratory motion has been identified as a crucial factor in achieving high resolution Nuclear Medicine (NM) imaging. Many motion correction approaches have been studied and they are seen to have advantages over simpler approaches such as respiratory gating. However, all motion correction approaches rely on an assumption or estimation of respiratory motion. This paper builds u...

2009
T. Nielsen P. Boernert

Introduction Motion during image acquisition can cause serious image artifacts. To overcome this problem the use of navigator signals ([1-3]) has been proposed combined with either realtime correction of the data acquisition or motion compensated reconstruction. The quality of the correction depends critically on the estimated motion derived from the navigator signal. Here, we present a fast, r...