نتایج جستجو برای: kazerun fault

تعداد نتایج: 64047  

F. Wang L. Fang,

In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...

F. Wang L. Fang,

In the fault diagnosis of automaton, the vibration signal presents non-stationary and non-periodic, which make it difficult to extract the fault features. To solve this problem, an automaton fault diagnosis method based on morphological component analysis (MCA) and ensemble empirical mode decomposition (EEMD) was proposed. Based on the advantages of the morphological component analysis method i...

2013
Hamid Reza Shaker Fatemeh Shaker

This paper deals with the stability of continuous-time multidimensional nonlinear systems in the Roesser form. The concepts from 1D Lyapunov stability theory are first extended to 2D nonlinear systems and then to general continuous-time multidimensional nonlinear systems. To check the stability, a direct Lyapunov method is developed. While the direct Lyapunov method has been recently proposed f...

کامیاب , عباداله, جاویدی , محمد حسین , ساده, جواد ,

Conventional fault location methods using voltages and currents of one terminal are not applicable to multiterminal transmission lines. So far some techniques have been presented to solve fault location problem for multi-terminal transmission lines. In these methods, lumped or distributed frequency domain models of transmission lines have been used. In multi terminal lines, faulty section shoul...

دشتی, رحمن , قاسمی, محسن ,

In this paper, an improved impedance based method has been proposed for fault location in power distribution network with presence of photovoltaic distributed generation resources. Within this method, current and voltage are measured at the beginning of feeder and at the location of distributed generation resources. The π line model is used for improving the accuracy of the suggested method....

2017
Farangis Sharifi Soheila Nouraei Nader Sharifi

OBJECTIVE This study assessed the factors affecting the choice of type of delivery with breast feeding in Iranian mothers. METHODS This Cross section descriptive analytic study was performed using a random sampling technique, using data from 400 pregnant women who attended the maternity centers in Borazjan and Kazerun in Iran in 2014. A questionnaire covering demographic characteristics, mode...

Journal: :the modares journal of electrical engineering 2008
a. r. sadoughi m. m. ebrahimi a ebrahimi2

different methods for detecting broken bars in induction motors can be found in literature. many of these methods are based on evaluating special frequency magnitudes in machine signals spectrums. current, power, flux, etc are among these signals. frequencies related to broken rotor fault depend on slip. in industrial environment due to some phenomena - such as load oscillation, other faults an...

ژورنال: محاسبات نرم 2013

With advances in computer networks, special attention has been paid to Wireless Sensor Networks (WSN). Because of their wireless nature, the probability of the fault occurrence in such networks is high. There has been a lot of research conducted on the field of fault detection in WSN. Among the fault detection methods, the disturbed ones are more important because they outperform other methods ...

دشتی, رحمن , ساده, جواد ,

Accurate locating of fault in power distribution system (PDS) can significantly improve the reliability indices. In this paper, a new simple and practical method is proposed for estimating the section and distance of fault in PDS. In the proposed method, at first the protective devises are allocated and then specially set in such a way that they are coordinated and the unique current pattern is...

Characteristics of ground motions close to the earthquake source can be considerably different from those of far-field motions which should be considered in design process of structures. The current study aimed to present new design response spectra for Iranian seismic design code taking into account the near-fault effects. For this purpose, a new attenuation relation based on the ground motion...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید