نتایج جستجو برای: iodide ion selective electrode

تعداد نتایج: 461721  

Journal: :physical chemistry research 2015
maryam hosseini bahram ghalami-choobar mohammad ali zanjanchi

in this work, the results concerning to the mean activity coefficient measurements for nacl in the (glycerol + water) system using the potentiometric method are reported. the potentiometric measurements were performed on the galvanic cells without liquid junction of the type: ag|agcl|nacl (m), glycerol (wt%), h2o (1 - wt)%|na-ise, in various mixed solvent systems containing 0, 5, 10, 20 and 30 ...

پایان نامه :وزارت علوم، تحقیقات و فناوری - دانشگاه پیام نور - دانشکده علوم پایه 1388

چکیده ندارد.

Journal: :journal of physical & theoretical chemistry 2004
hossein aghaie karim zare ali reza abedin mehran aghaie

a highly selective electrode for bromide ion based on aza pyrilium derivative as an excellentionophore is described.the sensor exhibits a good linear response with a slope of ( 60±1 ) mv per decadeover the concentration range of ( 1×10-3 – 9×10-6 m ) , and a detection limit of ( 3×10-6 m ) of bromideions .the electrode response is independent of ph in the range of(4.0 –9.5).selectivity coeffici...

2017
Marcel A. G. Zevenbergen

This work presents a flexible miniaturized ion-selective sensor consisting of a solidcontact reference electrode (RE) and ion-selective electrodes (ISE) fabricated on the same foil. The flexible ion sensor was based on AgCl electrodes screen printed on polyethylene terephthalate foil. The RE was formed by casting a mixture of plasticized polyvinylchloride (PVC) and KCl on the AgCl electrode. Th...

Journal: : 2022

Metformin in its protonated form as metformin hydrochloride is used worldwide an advanced antidiabetic drug for type 2 diabetes. Hyperinsulinemia and insulin resistance of cells are the main causes this disease. For patients with diabetes, (MET) works by improving cell sensitivity to insulin.
 It has been shown that methyl orange (MO) forms ionic associate can be isolated solid suitable cr...

2014
R. Govindan D. Alamelu Vittal Rao

Coated wire lithium ion selective electrode was fabricated using lithium ionophore-VI, 2-nitrophenyl octyl ether (NPOE) and potassium tetrakis(p-chlorophenyl)borate (KTpClPB) on platinum wire. Lithium ion selective electrode was giving Nernstian response from 10 -1 M to 10 -4 M with a detection limit of 3x10 -5 M. The calibration slope of this lithium ion selective electrode was found to be 58....

A. Islamnezhad M. Kia Sh. Shariati

In order to preparing strontium ion selective electrode 6-(4- nitropheny1)-2-pheny14, 4- dipropy1-3, 5-diaza-bicyclo [3, 1, 0] hex-2-ene (NPDBH) was used as an ionophore. This electrode responds to Sr (II)ion with a sensitivity of 28.2 ± 0.5 mV/decade over the range 1.0 x 10-6 to 1.0 Mat pH 3.0-10.0. Thelimit of detection was 2.4 x 10-7 M. The influences of membrane composition, the pH of the t...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید