نتایج جستجو برای: intracranial translucency

تعداد نتایج: 47701  

2014
Anne E Chambers Walter E Mills Imma Mercadé Francesca Crovetto Fatima Crispi Laia Rodriguez-Revenga Bodi Michael Pugia Aurea Mira Luis Lasalvia Subhasis Banerjee Elena Casals Eduard Gratacos

BACKGROUND Previous studies showed that soluble LHCGR/hCG-sLHCGR concentrations in serum or plasma combined with PAPP-A and free βhCG significantly increased the sensitivity of Down's syndrome screen at early pregnancy without altering the false positive rate. The goal of the present study was to further examine the role of sLHCGR forms as combinatorial markers and to investigate whether sLHCGR...

Journal: :International journal for quality in health care : journal of the International Society for Quality in Health Care 2013
Andrew J Sims Kim Keltie Julie Burn Stephen C Robson

OBJECTIVE To assess clinical measurement competency by two sequential test formulations [resetting sequential probability ratio test (R-SPRT) and learning curve cumulative summation (LC-CUSUM)]. DESIGN Numerical simulation and retrospective observational study. SETTING Obstetric ultrasound department. PARTICIPANTS Cohorts of 10,000 simulated trainees and 62 obstetric sonographers training...

Journal: :Sao Paulo medical journal = Revista paulista de medicina 2001
G L Acácio R Barini W Pinto Júnior R L Ximenes H Pettersen M Faria

CONTEXT The literature shows an association between several ultrasound markers and chromosome abnormality. Among these, measurement of nuchal translucency has been indicated as a screening method for aneuploidy. The trisomy of chromosome 21 has been most evaluated. OBJECTIVE To define the best fixed cutoff point for nuchal translucency, with the assistance of the ROC curve, and its accuracy i...

2011
Martin Hynek David Stejskal Jana Zvárová

Objectives: To evaluate and compare the performance of various quality control methods for nuchal translucency (NT) measurements. Methods: Fetal NT measurements performed over a oneyear period in a single center were used for the study. The retrospective quality review methods proposed by the Fetal Medicine Foundation (FMF) and the Woman & Infants Hospital of Rhode Island (WIHRI) were assessed ...

Journal: :Fetal diagnosis and therapy 2010
Mark I Evans Eugene Pergament

OBJECTIVE To determine the relative contribution of nuchal translucency (NT) to the biochemical detection rates of combined screening for trisomies 13 and 18 in two healthcare systems practicing different quality-control systems of nuchal measurement. METHODS De-identified data collected from the Fetal Medicine Foundation in the United Kingdom and laboratory data from NTD laboratories in the ...

2009
Deborah Wye Ron Benzie

The nuchal translucency (NT) scan provides an opportunity to examine fetal anatomy. Current opinion on the advantages and limitations of assessing fetal anatomy at this early gestation is divided. Two case studies from our centre will be presented where assessing fetal anatomy was of great benefit - one in finding abnormalities, the other in excluding them. These cases along with review of the ...

2015
Michael R. Andersen

Objectives: To compare two different dual-curing resins cement interfaces between low translucency and high translucency lithium disilicate glass-ceramics in vitro. M~aterials and Methods: ISO 11405 was modeled by using a standardized dumb-bell test to compare the tensile bond strength of two different resin cement interfaces ofa low translucency lithium disilicate ceramic to a high translucenc...

Journal: :American journal of obstetrics and gynecology 2006
Aris T Papageorghiou Kyriaki Avgidou Kevin Spencer Barry Nix Kypros H Nicolaides

OBJECTIVE The purpose of this study was to examine the sonographic features of trisomy 13 at 11 to 13(+6) weeks of gestation. STUDY DESIGN This was a retrospective study that examined the features of trisomy 13 at the ultrasound scan at 11 to 13(+6) weeks of gestation, which in our center is performed for the measurement of crown-rump length, nuchal translucency thickness, and fetal heart rat...

Journal: :Kathmandu University medical journal 2013
S Karki K S Joshi S R Tamrakar S Regmi K Khanal

BACKGROUND Nuchal translucency (NT) is the fluid collection behind the fetal neck which can be measured by ultrasound at 11-14 weeks of gestation. Increase in the nuchal translucency thickness is associated with various congenital anomalies. OBJECTIVE To study the relationship between nuchal translucency thickness, crown rump length and gestational age in normal fetus. METHODS Prospective a...

Journal: :CoRR 2017
Philipp Urban Tejas Madan Tanksale Alan Brunton Bui Minh Vu Shigeki Nakauchi

Advances in multimaterial 3D printing have the potential to reproduce various visual appearance attributes of an object in addition to its shape. Since many existing 3D file formats encode color and translucency by RGBA textures mapped to 3D shapes, RGBA information is particularly important for practical applications. In contrast to color (encoded by RGB), which is specified by the object’s re...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید