نتایج جستجو برای: implant length
تعداد نتایج: 352437 فیلتر نتایج به سال:
PURPOSE The complicated relationships between mandibular bone components and dental implants have attracted the attention of structural mechanics researchers as well as dental practitioners. Using the finite element method, the present study evaluated various bone and implant parameters for their influence on the distribution of von Mises stresses within the mandible. MATERIALS AND METHODS Va...
The purpose of this study is to compare the stress of the bone around the mini-implant under the two kinds of force: the composite force which contains torque and traditional single force. There were 96 finite element models formed by the combination of mini-implant and bone, with diameters of 1.2 mm, 1.6 mm, 2.0 mm and corresponding length being 6 mm, 8 mm, 10 mm, 12 mm, respectively. Each siz...
Effect of mini-implant length and diameter on primary stability under loading with two force levels.
Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...
introdouction: although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...
background: the success of dental implants depends on the manner in which stresses are transferred to the surrounding bone. an important consideration is to design an implant with a geometry that will minimize the peak bone stresses caused by standard loading. the aim of this study was to assess the infl uence of implant thread geometry on biomechanical load transfer and to compare the differen...
BACKGROUND/AIM Unstable intertrochanteric (IT) fractures, especially fractures with a reverse or transverse fracture line, have tendencies to make significant impaction on shortening of the femoral neck and lower extremity. The biomechanical complexity of the fracture, the type and the position of the implant are known to influence postoperative outcome. The aim of this study was to compare cha...
The placement of dental implants in the anterior maxilla is a challenging for the clinicians because of patients exacting esthetic demands and difficult pre existing anatomy. Esthetic implant therapy in the anterior maxilla is dependent on multiple factors including the lip drape, the implant position and the available peri implant soft tissue . The dental implants provide a realistic treatment...
The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral su...
PURPOSE Altered mandibular sensation following implant surgery may result in liability claims. Therefore the authors conducted a retrospective analysis of all liability claims related to persistent altered sensation following placement of mandibular implants reported to the Medical Consultants International (MCI) Company from 1992 to 1999. MATERIALS AND METHODS Reports related to persistent a...
This clinical study assessed at 5 years both implant survival and peri-implant tissue architecture of immediately provisionalized implants placed 4 to 6 months following augmentation with demineralized bovine bone allograft and collagen membrane. Of 23 implants in 19 patients, one implant failed prior to loading (95.6% survival). Implant tissue relationships were stable following implant placem...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید