نتایج جستجو برای: hybrid phantoms

تعداد نتایج: 202911  

2005
Gaetano Compagnone Laura Pagan Carlo Bergamini

Entrance skin dose (ESD) is an important parameter for assessing the dose received by a patient in a single radiographic exposure. The most useful way to evaluate ESD is either by direct measurement on phantoms using an ionization chamber or using calculations based on a mathematical model. We compared six phantoms (three anthropomorphic, two physical, and one mathematical) in 11 standard clini...

Journal: :Polymer Engineering and Science 2023

Abstract The main challenge of ultrasound‐guided minimally invasive surgeries is to carry out treatments through small boreholes in the patient's body surface with sub‐millimetric accuracy and facility offered by ultrasound instruments. Thus, phantoms' biomimetic appearances, acoustic characteristics, mechanical properties are essential for healthcare professionals. In this study, gelatin 3D‐pr...

2014
Ryan L. Grant Paige A. Summers James L. Neihart Anthony P. Blatnica Narayan Sahoo Michael T Gillin David S. Followill Geoffrey S. Ibbott

The delivery of accurate proton dose for clinical trials requires that the appropriate conversion function from Hounsfield unit (HU) to relative linear stopping power (RLSP) be used in proton treatment planning systems (TPS). One way of verifying that the TPS is calculating the correct dose is an end-to-end test using an anthropomorphic phantom containing tissue equivalent materials and dosimet...

Journal: :Annals of the ICRP 2016
C H Kim Y S Yeom T T Nguyen Z J Wang H S Kim M C Han J K Lee M Zankl N Petoussi-Henss W E Bolch C Lee B S Chung

The International Commission on Radiological Protection (ICRP) reference male and female adult phantoms, described in Publication 110, are voxel phantoms based on whole-body computed tomography scans of a male and a female patient, respectively. The voxel in-plane resolution and the slice thickness, of the order of a few millimetres, are insufficient for proper segmentation of smaller tissues s...

Journal: :Journal of biomedical optics 2016
Rolf B Saager Alan Quach Rebecca A Rowland Melissa L Baldado Anthony J Durkin

We present a method for low-cost fabrication of polydimethylsiloxane (PDMS) tissue simulating phantoms with tunable scattering spectra, spanning visible, and near-infrared regimes. These phantoms use optical polishing agents (aluminum oxide powders) at various grit sizes to approximate in vivo tissue scattering particles across multiple size distributions (range: 17 to 3 μm). This class of tuna...

2008
Martin Schläger

This paper describes the mathematical efficiency calibration of the whole-body counter at Forschungszentrum Jülich using Monte Carlo codes and mathematical anthropomorphic phantoms. As a prerequisite for the Monte Carlo simulations a precise model of the 4 high-purity germanium (HPGe) detectors had to be developed. Because the technical data provided by the manufacturer were not sufficient for ...

Journal: :Magnetic resonance in medicine 2016
Tri M Ngo George S K Fung Shuo Han Min Chen Jerry L Prince Benjamin M W Tsui Elliot R McVeigh Daniel A Herzka

PURPOSE Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedic...

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

Journal: :Journal of lipid research 2011
Xin-Gui Peng Shenghong Ju Yujiao Qin Fang Fang Xin Cui George Liu Yicheng Ni Gao-Jun Teng

We evaluated dual-echo Dixon in-phase and out-of-phase (IP-OP), chemical shift imaging (CSI), and (1)H MRS (hydrogen MR spectroscopy) in estimating fat content (FC) in phantoms and in livers of mice. Phantoms were made according to the volume percentage of fat ranging from 0% to 100%. The three MR methods were performed to measure FC in phantoms and in livers of obese leptin-deficient (ob/ob), ...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید