Experiments were conducted to measure condensation heat transfer of steam-ethanol mixtures on a horizontal smooth tube. Heat flux and vapor-to-surface temperature difference accurately measured over wide range mass concentration ethanol (0.001%, 0.005%, 0.01%, 0.025%, 0.05%, 0.1%, 0.5% 1.0%.) at atmospheric pressure. The present work extends earlier data Murase et al. (2007) Ali (2013) lower hi...