نتایج جستجو برای: glaucoma drainage implant

تعداد نتایج: 112612  

Journal: :International Journal of Ophthalmology 2020

2018
Grace M. Wang Daniel Thuente Brenda L. Bohnsack

Purpose Congenital ectropion uvea is a rare anomaly, which is associated with open, but dysplastic iridocorneal angles that cause childhood glaucoma. Herein, we present 3 cases of angle-closure glaucoma in children with congenital ectropion uvea. Observations Three children were initially diagnosed with unilateral glaucoma secondary to congenital ectropion uvea at 7, 8 and 13 years of age. Th...

2017
Nikolaos Dervenis Athanasia Maria Mikropoulou Panagiotis Dervenis Amanda Lewis

BACKGROUND XEN glaucoma implant (XEN gel stent, Aquesys, Inc) is a new minimally invasive device approved for the treatment of glaucoma. CASE PRESENTATION A 45 year old female was being followed and treated for primary open angle glaucoma in our tertiary referral center. Due to failure of medical treatment in controlling the glaucoma, surgery was offered to the patient. The XEN 45 μ-fistula i...

Journal: :Journal of Clinical Ophthalmology and Research 2013

Journal: :European journal of ophthalmology 2000
S Celebi G Alagoz U Aykan

PURPOSE We reviewed the rare ocular findings of Sturge-Weber syndrome (SWS) and the results of implantation of the Ahmed valve in cases associated with glaucoma. METHODS Seven patients (range 18 to 52 years) diagnosed as SWS were reviewed as clinical findings over two years. An anterior chamber maintainer was placed in patients with glaucoma to maintain stable intraocular pressure and minimiz...

Journal: :Bulletin de la Societe belge d'ophtalmologie 2009
J Jacob I Stalmans T Zeyen

PURPOSE To evaluate the clinical outcome of patients who received an Ahmed or Baerveldt implant for refractory glaucoma at the University Hospitals Leuven and to identify the factors which may influence the outcome. METHODS Retrospective study including 62 eyes with uncontrolled glaucoma, who underwent the implantation of a drainage device between January 2002 and December 2008. Criteria for ...

Journal: :Archivos de la Sociedad Espanola de Oftalmologia 2012
T Colás-Tomás E Gutiérrez-Díaz P Tejada-Palacios A Barceló-Mendiguchía E Mencía-Gutiérrez

PURPOSE To evaluate the results and long-term complications of glaucoma drainage devices (GDD) in paediatric patients (0-15 years). METHODS Retrospective cohort study was conducted on 17 implanted glaucoma drainage devices from July 1994 to April 2007 in 14 patients (17 eyes). In two patients (3 eyes) a Molteno GDD (MGDD) was implanted, and in 12 patients (14 eyes) an Ahmed GDD (AGDD) was use...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید