نتایج جستجو برای: gafchromic film
تعداد نتایج: 90975 فیلتر نتایج به سال:
Measurement of skin dose variations produced by a silicon-based protective dressing in radiotherapy.
Variations in skin dose caused by a silicon-based burn dressing used in radiotherapy during treatment have been investigated. Measurement of these variations in skin dose has been achieved using thermoluminescent dosimeters (TLDs) and Gafchromic film. For a 6 MV x-ray beam results have shown that an approximately 0.4 mm thick silicon mesh dressing increases the average surface dose by approxima...
PURPOSE Well-known defect of TG-43 based algorithms used in brachytherapy is a lack of information about interaction cross-sections, which are determined not only by electron density but also by atomic number. TG-186 recommendations with using of MBDCA (model-based dose calculation algorithm), accurate tissues segmentation, and the structure's elemental composition continue to create difficulti...
Assessment of skin dose delivered to patients from radiotherapy x-ray beams should be performed both inside and outside the prescribed treatment fields. A multilayer Gafchromic film detector which has high sensitivity for detection of radiation can be used to measure skin dose in a two-dimensional map over the skin surface if required. This is an advantage over other detectors, which only provi...
PURPOSE To study EBT3 GafChromic film in low-energy protons, and for comparison purposes, in a reference (60)Co beam in order to use it as a calibrated dosimetry system in the proton irradiation facility under construction within the framework of the Oncological Therapy with Protons (TOP)-Intensity Modulated Proton Linear Accelerator for RadioTherapy (IMPLART) Project at ENEA-Frascati, Italy. ...
EBT2 film is widely used for quality assurance in radiation therapy. The purpose of this study was to investigate the homogeneity of EBT2 film among various lots, and the dose dependence of heterogeneity. EBT2 film was positioned in the center of a flatbed scanner and scanned in transmission mode at 75 dpi. Homogeneity was investigated by evaluating gray value and net optical density (netOD) wi...
Introduction: The complex geometry of breast and also lung and heart inhomogeneities near the planning target volume (PTV) result in perturbations in dose distribution. This problem can result in overdosage or underdosage in the match region of the three treatment fields. The purpose of this study is to create a homogeneous dose distribution in the match region between the supraclavicular and t...
Small photon field used in the intensity modulated radiotherapy (IMRT) and stereotactic radio surgery (SRS). It is difficult to measure beam profile and output factor because of electron disequilibrium, partial shutting of source because of this challenges, we need the good detector. This article is collection of 5 or more article and summary of the results of EBT3 that compared with EBT2 film ...
نمودار تعداد نتایج جستجو در هر سال
با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید