نتایج جستجو برای: flexible intramedullary nail

تعداد نتایج: 129006  

Journal: :Bio-medical materials and engineering 2003
A H Murdoch D E T Shepherd K J Mathias E C Stevenson

This paper describes the design of a retractable intramedullary nail for the humerus that does not require inter-locking screws. The developed nail has a series of fins which open out from the casing to grip the medullary canal of the bone, thus securing it in position. Prototypes of the nail have been mechanically tested using static compression, dynamic compression and static torsion tests. D...

1995
W. J. Viant

The CAOS system aims to assist the orthopaedic surgeon in performing intramedullary nail locking, through the introduction of suitable technology into the operating theatre environment. The system comprises three components, the Smart Image Intensifier, Trajectory Tactician and Intelligent Drill Guide. The Trajectory Tactician is tailored to the requirements of intramedullary nail locking. The ...

Journal: :Journal of orthopaedic surgery 2012
Atul F Kamath Daniel Austin Gwo-Chin Lee

Reconstruction for concurrent infection of an ipsilateral total hip arthroplasty (THA) and total knee arthroplasty (TKA) is a challenge. We report a 2-stage reconstruction of a THA for chronic infection of both the THA and TKA with severe femoral bone loss secondary to interprosthetic fractures. The reconstruction involved using a custom-made, temporary, antibiotic-impregnated PROSTALAC spacer ...

Journal: :The archives of bone and joint surgery 2013
Hossein Aslani Ali Tabrizi Ali Sadighi Ahmad R Mirbolook

BACKGROUND In children, inappropriate treatment of open femoral fractures may induce several complications. A few studies have compared the external fixator with flexible intramedullary nails in high-grade open femoral fractures of children. The present study aims at comparing results of these two treatment methods in open femoral fractures. METHODS In this descriptive analytical study, 27 pa...

Journal: :Journal of functional biomaterials 2015
Yan Zhou Luke A Perkins Guodong Wang Dongsheng Zhou Hong Liang

Internal fixations provide fast healing but their failure remains problematic to patients. Here, we report an experimental study in failure of three typical cases of metals: a bent intramedullary stainless steel nail, a broken exterior pure Ti plate, and a broken intramedullary stainless steel nail. Characterization of the bent nail indicates that those metals are vulnerable to corrosion with t...

2012
S. Jain P. Harwood

We performed this systematic review to evaluate tibial lengthening procedures with the use of an intramedullary nail. We investigated the hypothesis that lengthening over a nail can reduce the time spent in an external fixator and increase the rate of consolidation thereby reducing the risk of complications and improving patient satisfaction. We conducted a comprehensive literature search using...

2015
Jia-Guo Zhao Jia Wang Chen Wang Shi-Lian Kan James Franklin Kellam.

Multiple meta-analyses have been published to compare intramedullary nail and plate for treating humeral shaft fractures; however, results are discordant.The purposes of current study were to perform a systematic review of overlapping meta-analyses comparing intramedullary nail and plate fixation for the treatment of humeral shaft fractures, to appraise the methodological quality and the qualit...

Journal: :trauma monthly 0
indranil v kushare division of orthopedics, nationwide children’s hospital, columbus oh, usa matthew e oetgen division of orthopaedic surgery and sports medicine, children’s national medical center, washington dc, usa suzanne j walters division of orthopaedic surgery and sports medicine, children’s national medical center, washington dc, usa; division of orthopaedic surgery and sports medicine, children’s national medical center, washington dc, usa. tel: +1-2024764535, fax: +1-2024764613

we present a case report of acute spontaneous knee hemarthosis due to erosion of the nail through the knee joint capsule in a boy, seven months following retrograde flexible nailing for fractured femur. careful positioning of the location of the insertion site of flexible nails and proper nail tip management are important to avoid this rare late complication.

2015
Joachim Horn Øyvind Grimsrud Anita Hoddevik Dagsgard Stefan Huhnstock Harald Steen

PURPOSE We assessed whether an intramedullary lengthening device would reduce the problems normally associated with the external fixation technique. We also wanted to determine whether it is a reliable construct for limb lengthening and deformity correction in the femur. PATIENTS AND METHODS We conducted a matched-pair comparison of 30 femoral lengthenings, 15 with a motorized intramedullary ...

Journal: :Ortopedia, traumatologia, rehabilitacja 2011
Alessandro Geraci Ricciardi Alberto Rossella Mingozzi Michele Spinelli

BACKGROUND The incidence of fractures in the trochanteric area has risen with the increasing numbers of elderly persons with osteoporosis. The imperative goals of treatment are early mobilization by means of stable fixation using as minimally invasive a procedure as possible. Nowadays, there is an increasing interest in intramedullary nailing, especially for unstable intertrochanteric fractures...

نمودار تعداد نتایج جستجو در هر سال

با کلیک روی نمودار نتایج را به سال انتشار فیلتر کنید