a facile and highly efficient method have been developed for the preconcentration of the mercury content in crude oil and gasoline samples after digestion with microwave-assisted digestion. octadecyl silica membrane disk has been modified by the recently synthesized triazene ligand, (e)-1-(2-ethoxyphenyl)-3-(4-nitrophenyl) triaz-1-ene (ent), then the modified membrane was used for the preconcen...
We describe an integrated, molecular-absorbance, atomic absorption instrument for studying metal/ligand binding in clinical samples. For an interface between the "high-performance" liquid chromatograph and the atomic absorption instrument we used a flow-injection sample manipulator, thus allowing both the chromatograph and the atomic absorption detector to operate at their separate optimum cond...
lithum can be de termined both by atomic absorption spectroscopy andflame emission spectroscopy. we have used the later method with a zeiss model pmqli spectro photometer fitt ed with ante-chamber atomizer and a potensiome rric line recorder. accurate ana lysis for the clement was acco mplished due to a sophisracared measuring instrument.
A simple attachment to enhance the sensitivity of flame atomic absorption spectrometry (FAAS) is described along with some performance results and practical applications. An historical review is also presented.
The aim of this study was to determine and compare the concentration of copper (Cu) in liver and muscle of two fish species Squalius cephalus and Capoeta capoeta gracilis. The fish were caught in four sampling sites along Tajan River, Mazandaran Province, northern Iran. The concentration of Cu was determined using flame atomic absorption spectrometry. There were significant differences (P
Orthodontic miniscrews gained popularity in the last decade due to the possibility of reduced treatment time, low cost, small dimensions and low morbidity rate. Absolute anchorage with no dental side effects make orthodontic mini implants an attractive choice for orthodontists. Although these advantages provide optimal clinical solutions, some characteristics must be taken into account when cho...
IN CONVENTIONAL atomic absorption spectrophotometry a solution of the sample is introduced into the flame as an aerosol by means of a nebulizer. However, commercial nebulizers are only about 5 efficient in forming fine droplets suitable for atomization by the flame ( I ) . Furthermore, a solution aspirated at a usual rate of 3-5 ml/min for about 10 sec produces a concentration signal extending ...